sciscape Publications
← All publications

A contact metric kept geometric SEEG templates and site labels fixed across full layouts of consistent contact differences in four records

We tested whether a software pair layout changes whole-vector geometric median templates from the same public SEEG contact signals. The primary test used 134 stimulation sites and 536 test pulses from four records of OpenNeuro ds004457 version 1.0.2. Each layout retained the same full contact contrast space. In the 20 to 100 ms window, a star layout changed 46 of 536 predicted site labels compared with adjacent pairs. A complete layout changed 25. A contact metric kept every template and label fixed to numerical precision. A fifth record with identical layouts gave a negative control. The reader used one fixed contact covariance. Equal-record accuracy was 42.96% for the contact median and 44.21% for the arithmetic mean. These tests did not establish an accuracy gain. The proof requires consistent pair signals and the same full contact contrast space. New raw downloads passed all source hashes. Raw extraction and a fresh analysis reproduced all 820 result arrays exactly. Independent numerical checks also passed. The package preserves compact data, source hashes, retrieval code, fitted templates, site decisions, the proof, and three figures. These reused clinical records do not give a prospective BCI performance estimate.

stereoelectroencephalography · geometric median · bipolar recordings · contact metric · response templates · site classification

Admitted 0 citing publications

References

6
  1. usesTwo covariance targets kept SEEG site decisions fixed across full layouts of consistent contact differences but differed on 115 of 536 pulses in four records sci:sha256:03ea8f7a7284154912c2582f91b7b5908c0548ac332841e730f46cb091b4b9f6

    We used its voltage bins, fixed contact and pulse rules, raw source manifest, and contact projection code. We also reproduced all of its saved constant-target arithmetic reader labels.

  2. usesSample medians across five pulses created 70 to 110 Hz power after 4 to 30 Hz Fourier projection at 83 SEEG sites in eight people sci:sha256:5ffefa54d4515654331ef4bbb7ff7f314651825a7e7efc6ee5d8fca5c9146cc8

    We adapted its whole-vector geometric median solver under GPL-3.0-or-later. It supplied the numerical template method. We did not use its HAPwave voltage data.

  3. usesA SEEG reader kept an after-pulse site accuracy gain after removal of linear trend use in five offline patient sessions sci:sha256:bb2ab1feb65907a20b72918e38ceb558f7e95be8c82f8d97c390865040db3bf4

    We used its raw MEF bin extraction rule and code lineage through the input publication. This rule enabled exact replay from newly retrieved source files.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analysis used OpenNeuro ds004457 version 1.0.2; its cached voltage bins and event metadata are retained as CC0 inputs.

  5. usesdoi:10.1523/JNEUROSCI.1325-22.2023

    This is the source paper for the clinical stimulation dataset used in the analysis.

  6. doi:10.1073/pnas.97.4.1423

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.