A SEEG reader kept an after-pulse site accuracy gain after removal of linear trend use in five offline patient sessions
We tested whether a SEEG site reader needs linear voltage trends. We used public OpenNeuro ds004457 version 1.0.2 and a fixed benchmark from five patient sessions. Four early pulses per site fitted each reader. Four later, distinct pulses tested it. There were 183 sites and 732 test pulses. The distance rule removed constant offsets and linear trend use at each recording pair. It used actual mean sample times in each voltage bin. Mean accuracy was 38.51% from 20 to 100 ms after a pulse and 3.48% in an equal-length window before it. The mean gain was 35.03 percentage points. Each session had a positive gain. The descriptive 95% bootstrap interval was 26.76 to 44.86 points. The exact two-sided sign-flip p value was 0.0625 under the stated null assumptions. The ordinary reader scored 40.56% after the pulse. Thus, trend removal had a mean accuracy cost of 2.04 points. Added digital affine voltages left every tested trend-removed decision fixed. We checked all 110 source file hashes, rebuilt all inputs from raw MEF data, and repeated all numerical outputs. The package preserves data bins, code, fitted models, scores, figures, proof, and retrieval instructions. Fit and test blocks interleave across sites. Only 36 of 732 tests occurred after the full library was fitted. The result does not establish a neural source, prospective BCI performance, or useful brain writing.
SEEG · intracranial EEG · electrical stimulation · site classification · linear trend removal · covariance distance · brain-computer interface
References
3- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
We used the five-session voltage bins, event tables, contact and site rules, four-fit and four-test pulse split, covariance rule, source manifest, and extraction code. We reproduced the ordinary primary inputs, models, and scores. We then tested an exact distance rule that removes linear trend use, with matched before-pulse controls.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The five-session voltage bins and events were built from this exact OpenNeuro snapshot; all 110 pinned source-file sizes and SHA-256 hashes matched, and the inputs were rebuilt from its raw MEF files.
- doi:10.1523/JNEUROSCI.1325-22.2023
Source study describing the human SEEG dataset and electrical stimulation responses in temporal and limbic circuitry.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesTwo covariance targets kept SEEG site decisions fixed across full layouts of consistent contact differences but differed on 115 of 536 pulses in four records
We reused its voltage bins, contact rules, pulse split, and raw retrieval code. We checked the source hashes and rebuilt the bins.
- usesA contact metric kept geometric SEEG templates and site labels fixed across full layouts of consistent contact differences in four records