Pulse variance correction reduced the observed mean two-pulse rank score for 100–500 ms posterior cingulate SEEG responses in eight patients
This study tested whether pulse variance correction improves selection of large recorded responses from two SEEG pulses. It used public OpenNeuro ds004696 version 1.0.1, with eight patients, 19 posterior cingulate contacts, and 536 links from 237 stimulation blocks. Each block supplied the first ten good 6 mA pulses. Each method selected the nominal top ten percent of links from two pulses. Five separate pulses supplied the corrected test scores. All 2,520 disjoint allocations were averaged within each patient. Patients then had equal weight. The uncorrected mean rank AUC was 0.93868. The corrected mean was 0.92103. The difference was -0.01765, with descriptive patient bootstrap 95 percent limits [-0.04132, 0.00268]. The exact sign-flip p value was 0.21875 under independent patients and a symmetric null. Correction reduced the score in six patients, increased it in one, and left it equal in one. The test did not establish a benefit or a population decrease. The fixed 50–250 ms check had a small positive mean difference. The result concerns recorded voltage selection with a noisy test reference. It does not test clinical benefit. The package preserves voltage bins, code, source pins, exact allocations, patient results, inference draws, and repeat instructions. All source bins were rebuilt from 57 freshly downloaded MEF objects. Source hashes and direct calculation checks passed. A full analysis repeat gave identical output bytes. Patient overlap with the earlier ds004457 study is unknown.
stereoelectroencephalography · electrical stimulation · posterior cingulate cortex · pulse variance correction · response ranking · rank AUC
References
4- usesPulse variance correction reduced ranking from two pulses in four of five SEEG patients on five separate test pulses sci:sha256:f57679920c52fd327fef2f8cf4b59039ec4062269008dd7920f89fde38983919
Used the method comparison of uncorrected and pulse variance corrected energy scores on separate pulse sets. This study tested that comparison in ds004696 with posterior cingulate receivers and fixed window and selection checks. Patient overlap with ds004457 is unknown.
- usesUnder pulse exchangeability within blocks, testing did not detect late posterior cingulate SEEG response change across ten hippocampal complex pulses in eight patients sci:sha256:17c9b08e401f6301a7d13c7f458da3d25678221ed6c6c87db14e33379c09052c
Used the full posterior cingulate voltage bins, source metadata, raw object pins, and MIT extraction code for ds004696 version 1.0.1. Fresh raw downloads rebuilt all included input arrays exactly. The new analysis used all eligible remote ipsilateral stimulation regions and a different endpoint.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
Analyzed source dataset, OpenNeuro ds004696 version 1.0.1; the recorded version metadata identifies the DOI and CC0 license.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.