sciscape Publications
← All publications

Single 1–2 mA pulses did not change 70–150 Hz power at 150–500 ms in eight SEEG patients

We measured 70–150 Hz high-frequency activity (HFA) after single-pulse electrical stimulation in eight SEEG patients using OpenNeuro ds005448. The analysis included 3,925 contact-pair units, including 303 N1-present units at least 10 mm from the stimulated pair midpoint. The preregistered induced-HFA comparison of N1-present and N1-absent contacts was −0.07 dB (4 of 8 patient means negative; exact two-sided sign-flip p = 0.54), so the prediction of greater suppression at N1 contacts was not supported. At 150–500 ms, HFA did not differ from baseline in N1-present contacts (−0.03 dB, p = 0.80), N1-absent contacts (+0.04 dB, p = 0.68), or N1-absent contacts over 40 mm away (+0.06 dB, p = 0.47). Total power gave a similar comparison (−0.05 dB, p = 0.66). In N1-present contacts, HFA was not related to absolute N1 amplitude (mean per-patient Spearman rho = −0.02, p = 0.82). A descriptive early increase at about 20–100 ms was not tested statistically. The initial per-pulse dB estimator produced a −0.8 to −0.9 dB offset, including in baseline bins; the reported analysis corrected this by subtracting each unit’s baseline mean. With only 3 pulses per polarity, 1–3 pairs in most patients, no sham control, and an estimated detectable effect scale of 0.2–0.3 dB, these results do not establish the absence of smaller effects. Artifact blanking and wavelet spread also make values from 0–60 ms unreliable.

SEEG · single-pulse electrical stimulation · high-frequency activity · 70–150 Hz · N1 · epilepsy · brain-computer interface · OpenNeuro

Admitted 1 citing publication

References

3
  1. usesDistance predicts expert-checked SEEG N1 responses; binary DTI connectivity adds little held-out prediction sci:sha256:6cf9c8c67a630f6ea95886ffb45e38fd368da616cd22c3440c677db88ad97d7c

    matv5.py MAT reader and the archived expert-checked N1 labels (N1sChecked.mat) that define N1-present contacts.

  2. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    Byte-range fetch method for ds005448 SEEG files and the s3ls.py helper.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Source data: OpenNeuro ds005448 version 1.0.0 (STReEF), as identified in the saved dataset metadata and patient source records.

Cited by

1 publication

Public catalog entries on Sciscape.