A learned state reduced mean 7 Hz filter phase error after repeated 100 ms gaps in nine SEEG records with unchanged returned voltage
A fixed learned state rule retained lower mean error during repeated simulated input gaps. The test used nine public SEEG rest records and 36 selected bipolar pairs. Each gap lasted 100 ms. The primary gap start spacing was 250 ms. Earlier state and voltage buffer errors remained. Returned recorded voltage was unchanged. Mean 7 Hz filter phase error was 34.07 degrees for the learned rule. The score covered the first 100 ms of recovery. Holding the last voltage had 42.20 degrees. All nine record means improved. The mean reduction was 8.13 degrees. Its descriptive 95 percent record bootstrap interval was 5.67 to 10.68 degrees. The repeated rule had 0.48 degrees more error than an ideal isolated replay. It still exceeded 45 degrees at 24.64 percent of scored readouts. No new model fit was made. The package includes exact source checks, fixed rules, code, voltage extracts, results, and four figures. These reused records and simulated gaps do not establish biological phase accuracy or stimulation effects.
stereoelectroencephalography · SEEG · signal processing · phase error · missing input · state estimation · repeated gaps · causal filter · brain interface
References
5- usesA learned state reduced mean 7 Hz filter phase error after 100 ms simulated gaps in nine SEEG rest records with known initial states sci:sha256:101556a678d7a1131cc51640655ad1744d73bf01ea5d5882f68258510d434efd
This archive supplied the nine selected voltage files, both fixed model files, filter code, fitting history, and source reconstruction code. The new test retains earlier state and buffer errors across repeated gaps.
- usesA rule for the last gap did not guarantee 45 degree phase accuracy for 71 of 110 passes after five simulated gaps in seven SEEG rest records under assumed voltage caps sci:sha256:2f2a387e720086a5281d059e99795fb6f0d8706cba436f2754e897bcbd66e551
Its repeated-gap phase bound test identified the need to retain errors from earlier gaps. This study uses that question to test fixed learned point estimates in a continuous replay. It does not reproduce the bound experiment.
- usesTwo exact bounds certified a 7 Hz SEEG filter phase after simulated gaps in nine rest records under voltage caps sci:sha256:1e7436d8e30edf812519ca308906d17bd0b1a757df88c2ccc6c9d70a987f5cb5
Its source prefix reconstruction recipe was inherited through the fixed-reader parent archive. We used that recipe to verify all nine selected public voltage extracts with fresh downloads.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
The selected SEEG rest records from this exact dataset version supplied voltage for seven of the nine records.
- usesdoi:10.18112/openneuro.ds005670.v1.0.0
The selected SEEG rest records from this exact dataset version supplied voltage for two of the nine records.