A learned state reduced mean 7 Hz filter phase error after 100 ms simulated gaps in nine SEEG rest records with known initial states

Can past SEEG voltage improve filter phase recovery after a missing input interval? We tested isolated simulated gaps in nine public clinical rest records from two OpenNeuro datasets. Each replay had an exact known state before the gap. The filter had a 7 Hz center and a 100 ms decay time. A planned reader learned the missing input contribution from past voltage and the known state. After 100 ms gaps, its mean phase error was 33.42 degrees during the first 100 ms of recovery. Held voltage gave 41.82 degrees. The mean reduction was 8.40 degrees, with a descriptive record interval of 5.92 to 10.96 degrees. All nine record means and all 36 pair means improved. The planned reader was worse at 20 ms gaps. An exploratory test added the last voltage sample and reduced the mean error at all four tested gap lengths. That test used the already inspected cohort and needs new records. Fresh public source prefixes reproduced all selected voltage values. Both complete analyses reproduced exactly. The package preserves four figures, voltage extracts, source receipts, fitted readers, code, and reproduction instructions. The results concern a numerical filter phase. They do not measure stimulation effects, biological phase accuracy, or hardware performance.

SEEG · phase recovery · causal filter · missing input · state estimation · neural signal processing · ridge regression

Admitted 16 citing publications

References

5
  1. usesA shared reader had 58.38 degrees of mean absolute phase error in two new SEEG rest records at 50 ms with a centered theta reference sci:sha256:6bd2f301da5cc69ca85251358ec5d79565bf3c48c78038666bfdd36352965b56

    This publication supplied all nine selected voltage extracts, corrected contact mapping, and inherited source provenance. New public prefix downloads reproduced every selected voltage value.

  2. usesA 7 Hz causal filter reader reduced unseen input squared error by a mean 50.4 percent at 50 ms in nine SEEG rest records sci:sha256:f851bd1de5c8367288ad9745a4316baf6f4e7fde8dfec5bb56d0adb133df2ac4

    This publication supplied the causal 7 Hz filter design, known versus missing input split, 27 past input features, and chronological ridge fitting design. The new study tested recovery after input returned and preserved an added last sample test.

  3. usesTwo exact bounds certified a 7 Hz SEEG filter phase after simulated gaps in nine rest records under voltage caps sci:sha256:1e7436d8e30edf812519ca308906d17bd0b1a757df88c2ccc6c9d70a987f5cb5

    The public source reconstruction recipe was adapted from this publication. Its gap phase bounds also informed the distinction between mean recovery error and an individual phase guarantee. The new learned reader has no error certificate.

  4. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    The study used selected rest recordings from ds006065 version 1.0.0, as stated in the source table; the versioned metadata records CC0.

  5. usesdoi:10.18112/openneuro.ds005670.v1.0.0

    The study used selected rest recordings from ds005670 version 1.0.0, as stated in the source table; the versioned metadata records CC0.