A fixed learned update reduced 7 Hz filter phase error in nine SEEG rest records with simulated 100 ms gaps every 250 ms
Repeated signal gaps can leave errors in a filter state and its recent voltage buffer. We tested 36 selected bipolar pairs from nine public SEEG rest records. We kept the earlier fitted models fixed. The main test used 100 ms simulated gaps every 250 ms. Each causal reader kept its own estimated state after each gap. The learned reader filled older voltage gaps with the last received sample. Mean absolute phase error over eleven recovery offsets from 0 to 100 ms was 34.10 degrees for the learned update. Voltage hold had 42.24 degrees, and zero input had 37.50 degrees. The learned reader had lower mean error in all nine records than either comparator. Its mean error was 0.50 degrees above a diagnostic with exact state and history. All main-interval state transition norms were below 0.654 when voltage history stayed fixed. One matrix allowed transient growth at a 200 ms gap interval. Independent recursive replay, hidden-input checks, two full analysis runs, and fresh public source reconstruction passed. The package has data, models, code, source receipts, results, and three figures. These are exploratory results on reused selected rest records. They concern numerical filter phase, not biological phase, hardware recovery, decoder accuracy, or stimulation benefit.
SEEG · signal processing · filter phase · state estimation · recording gaps · ridge regression · neuroscience
References
5- usesA learned state reduced mean 7 Hz filter phase error after 100 ms simulated gaps in nine SEEG rest records with known initial states sci:sha256:101556a678d7a1131cc51640655ad1744d73bf01ea5d5882f68258510d434efd
This experiment uses its fixed 100 ms gap models, filter code, voltage normalization values, nine input arrays, and selected pairs. It replaces isolated gaps with continuous repeated-gap replay and retained state and history errors.
- usesA shared reader had 58.38 degrees of mean absolute phase error in two new SEEG rest records at 50 ms with a centered theta reference sci:sha256:6bd2f301da5cc69ca85251358ec5d79565bf3c48c78038666bfdd36352965b56
The retained public voltage extracts and pair selection use this corrected cross-dataset data package. Its primed-contact name rule for record 01 and the source metadata are preserved.
- usesTwo exact bounds certified a 7 Hz SEEG filter phase after simulated gaps in nine rest records under voltage caps sci:sha256:1e7436d8e30edf812519ca308906d17bd0b1a757df88c2ccc6c9d70a987f5cb5
Its public prefix reconstruction method is retained through the direct parent. This run used the method to rebuild and check all nine voltage extracts exactly from public source files.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
This publication uses four selected bipolar pairs from seven records in OpenNeuro ds006065 version 1.0.0.
- usesdoi:10.18112/openneuro.ds005670.v1.0.0
This publication uses four selected bipolar pairs from two records in OpenNeuro ds005670 version 1.0.0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.