A patient offset from distant SEEG pairs reduced normative spectral error by 8–34% in 249 RAM patients
In 249 patients from the RAM free-recall datasets, a patient-specific offset estimated from the same patient’s covered bipolar SEEG pairs at least 40 mm from a target reduced leave-one-patient-out normative mean squared error by 8% to 34% across five spectral features. The analysis used 27,974 pairs from 256 patients, a map built from the 30 nearest pairs of other patients within 15 mm, and a prespecified plan. Reductions were 16% for relative theta power, 8% for relative alpha, 25% for relative beta, 25% for the 2–40 Hz aperiodic exponent, and 34% for log broadband power; Holm-adjusted p values ranged from 0.0002 to 0.0011. About half of patients improved for theta and alpha. An offset from another patient increased error by 48% to 76%. An offset from one distant pair increased error for every feature, but with two pairs broadband error decreased by 7%; therefore the original claim that fewer than five pairs always increased error was corrected. Results apply to one 60 s word-encoding segment, bipolar recordings, and RAM patients. There were no seizure-onset-zone or pathology labels, so the study did not test abnormality detection. The observed feature includes possible pathology, and the cause of the patient offset is unknown.
stereo-EEG · SEEG · normative maps · patient offset · spectral features · free recall · RAM
References
4- supportsSEEG pairs from one patient share spectral similarity across distances, including 40 mm or more sci:sha256:e3b03621910cb98055ae57b12626884d32ca96353e28a0c54ede9326820873ed
A patient offset from pairs at 40 mm or more predicts held-out pairs; this agrees with its long-range patient similarity.
- usesSEEG pairs from one patient share spectral similarity across distances, including 40 mm or more sci:sha256:e3b03621910cb98055ae57b12626884d32ca96353e28a0c54ede9326820873ed
Uses its per-pair feature table (results/pair_features.tsv) and its finding of a long-range patient component.
- supersedesPatient offsets from distant same-patient pairs reduced normative SEEG spectral error by 8–34% in 249 RAM patients sci:sha256:85b722e61f08070c398c917bc10a3165a515de4a3d7e58d631cc7df561d1c389
Corrects the title statement about offsets from fewer than 5 pairs (broadband power improved with 2 pairs). Same data, code and main results.
- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
The features come from its archived RAM SEEG spectra.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.