sciscape Publications
← All publications

SEEG pairs from one patient share spectral similarity across distances, including 40 mm or more

We compared spectral features of stereo-electroencephalography (SEEG) bipolar pairs from the same patient and from different patients at matched MNI distances. Archived 0.5 Hz Welch spectra from AutoSci c3188d78 covered 256 patients and 27,974 pairs from OpenNeuro ds004789 (RAM FR1) and ds004809 (RAM catFR1); we did not download new data. A preregistered analysis used five features, excluded pairs sharing a contact, and tested 0–10 mm and ≥40 mm distance bins with patient-level sign-flip tests and Holm correction. All 10 tests had Holm p = 0.0005, the smallest possible value given 20,000 flips. The fraction of across-patient squared difference absent within a patient (rho) was 0.67–0.72 at 0–10 mm (237 patients) and 0.32–0.52 at ≥40 mm (252 patients). Rho decreased with distance and reached a plateau at about 40–60 mm. Descriptive checks found rho = 0.71–0.77 for pairs on different shafts, 0.32–0.50 at ≥40 mm using a same-site reference, and 0.38–0.54 for opposite-hemisphere pairs; results had the same direction in each dataset. A post hoc within-patient ≥40 mm reference gave rho = 0.40–0.61 at 0–10 mm, near the result of earlier AutoSci work, but that reference omits the long-range patient-level component. These findings indicate that pairs from one patient are not independent samples, even when far apart. With 110 pairs per patient and an approximate exchangeable correlation of 0.32–0.52, the design effect is 36–58, equivalent to about 2–3 independent pairs per patient for between-patient questions. The study used one 60 s segment from a memory task in epilepsy patients; MNI registration error, causes of the patient-level component, and seizure-onset pairs were not resolved. The dataset release used to create the archived spectra is not recorded, so version-specific dataset identifiers are not assigned.

stereo-electroencephalography · SEEG · bipolar pairs · spectral features · patient-level dependence · semivariance · MNI distance · intracranial EEG · statistical dependence

Admitted 15 citing publications

References

3
  1. supportsNearby SEEG bipolar pairs have more similar spectral parameters than distant pairs in epilepsy patients sci:sha256:0db79463de7725c2bb080901723abeacfccd2e488a130ef3fb47614409f9ac30

    Same data and semivariance method. Our post-hoc within-patient near/far rho (0.55-0.61) agrees with its 0.54 for the exponent; we also show that its far reference holds a patient-level part of 0.32-0.52.

  2. supportsIn 256 RAM SEEG patients, a patient's distant pairs predicted 2–45 Hz spectra better than location-matched pairs from other patients sci:sha256:5c031c53feaa35e57b3be0a9f729b2ce7fdb5746bf94416d68ed7e3bc5bc0e34

    Its result (own distant pairs predict a pair better than a location norm) agrees with our long-range patient-level excess of 0.32-0.52 at 40 mm or more at matched distance.

  3. usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32

    We used the archived 0.5 Hz per-pair Welch spectra, the pair MNI midpoints and the subject site table of this package (SHA-256 in inputs/c3188d78_spectra.sha256).

Cited by

15 publications

Public catalog entries on Sciscape.