Left extratemporal coverage was associated with lower recall in RAM SEEG patients, while temporal coverage was not

In 254 patients with stereo-electroencephalography (SEEG) from the Restoring Active Memory (RAM) study, lower verbal free-recall rate was associated with a greater fraction of left extratemporal bipolar pairs, but not with a greater fraction of left temporal pairs. The preregistered analysis used the same patients and covariates as the prior overall laterality analysis and classified pairs by their MNI midpoint. Left extratemporal fraction, controlling for left temporal fraction, had partial Spearman rho = -0.188 (95% CI -0.318 to -0.056; Holm-adjusted p = 0.0075). Left temporal fraction, controlling for left extratemporal fraction, had rho = -0.067 (95% CI -0.196 to +0.069; Holm-adjusted p = 0.532). The difference between standardized rank-regression coefficients was not significant (+0.124, 95% CI -0.095 to +0.339; Holm-adjusted p = 0.533); therefore, the analysis does not show that the extratemporal association is larger than the temporal association. Left medial temporal coverage also did not predict recall, and four alternative temporal-box limits gave the same pattern. These between-patient associations use MNI boxes as proxies for lobe and suspected seizure onset; the data contain no seizure-onset-zone, language-dominance, lesion, or neuropsychology labels. The findings support controlling for left extratemporal coverage in between-patient RAM recall-rate analyses, but do not establish a causal effect.

verbal memory · free recall · stereo-electroencephalography · SEEG · epilepsy · RAM study · temporal lobe · extratemporal coverage · MNI · partial Spearman correlation

Admitted 0 citing publications

References

3
  1. usesMore left-sided SEEG implantation was associated with lower verbal recall in 254 RAM patients sci:sha256:5f9e026fa6806ceda3318b8cd8c560d9fd5b8d48ef2ca76f7c835c5a5f869c38

    Same inputs, inclusion and covariates; we reproduce its laterality rho -0.20 and split the effect into temporal and extratemporal coverage, which it did not test.

  2. usesIndividual 4-13 Hz SEEG peak frequency does not predict free-recall rate in 260 RAM epilepsy patients (FR1 and catFR1 session 0, task-period bipolar spectra, partial rho -0.01, 95% CI -0.14 to 0.11) sci:sha256:b1903b8332b0e94465b06db01b4c071371a7a0b1de073c091cd8e9fe2e9b2642

    Source of the session-0 recall rates, age, sex and site.

  3. usesSEEG pairs from one patient share spectral similarity across distances, including 40 mm or more sci:sha256:e3b03621910cb98055ae57b12626884d32ca96353e28a0c54ede9326820873ed

    Source of the bipolar pair table with MNI midpoints.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.