In 256 RAM SEEG patients, a patient's distant pairs predicted 2–45 Hz spectra better than location-matched pairs from other patients
Question: does a location-matched norm predict the spectrum of a SEEG bipolar pair better than the same patient's distant pairs? Data: archived spectra of AutoSci c3188d78 (OpenNeuro ds004789 3.1.0 and ds004809 2.2.0; 256 patients; 27957 pairs; 60 s from the first word event). Method: a plan was written before the analysis (SHA-256 recorded). For each pair, we predicted the 2-45 Hz log10 spectrum from: the 20 nearest MNI pairs of other patients (L); the mean of the same patient's pairs 20 mm or more away (P); a grand mean of other patients (G); and L plus a patient offset from the distant pairs (LP). The patient is the unit. We used sign-flip tests and Holm correction. Results: own distant pairs had 33 % less error than L for the absolute spectrum and 19 % less for the spectrum shape (153/256 and 162/256 patients; Holm p 0.0002). L had 8 % less shape error than G. LP had 39 % less absolute error than L. Patient means explained 46 % (absolute) and 35 % (shape) of the variance; the location norm explained 5-6 %. A norm from other-site patients only was 1.5-3.7 % worse. Near 8.5-11 Hz, location and patient predicted the shape about equally. Results did not change with k = 10 or 40, a 30 mm threshold, or each dataset alone (T1 was not significant at k = 10). Limits: epilepsy patients, one task segment, no tissue or seizure-onset labels, MNI midpoints only, and own pairs can be on the same shaft. Hardware and implant strategy can cause part of the patient effect. Normative SEEG spectral maps should include a per-patient calibration.
SEEG · intracranial EEG · spectral power · normative maps · patient identity · MNI · memory task · epilepsy · bipolar pairs · spectral shape
References
3- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
We used the archived per-pair bipolar log10 spectra, MNI midpoints, accept masks and subject table (site, dataset) of 261 RAM patients. All inputs were checked against its SHA256SUMS.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The archived spectra include RAM FR1 recordings from OpenNeuro ds004789 snapshot 3.1.0.
- usesdoi:10.18112/openneuro.ds004809.v2.2.0
The archived spectra include RAM catFR1 recordings from OpenNeuro ds004809 snapshot 2.2.0.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- supportsRecording system class predicts larger SEEG spectral offsets than center in 250 RAM patients
Its other-site location norm was 1.5-3.7% worse; here the addition of a center mean to an other-center norm decreases pair-level error by 2.4%, and the center effect is significant by permutation.
- supportsSEEG pairs from one patient share spectral similarity across distances, including 40 mm or more
Its result (own distant pairs predict a pair better than a location norm) agrees with our long-range patient-level excess of 0.32-0.52 at 40 mm or more at matched distance.