sciscape Publications
← All publications

Recording system class predicts larger SEEG spectral offsets than center in 250 RAM patients

We measured how much the recording center explains in SEEG bipolar spectra after electrode position, age, sex and task. We used archived spectra of 250 RAM patients from 8 centers (OpenNeuro ds004789 and ds004809, via AutoSci c3188d78). For each pair, a location norm was the mean log10 spectrum of the 20 nearest MNI pairs from patients of other centers. The patient offset was the mean pair residual at 2-45 Hz, adjusted for age, sex and dataset. The leave-one-patient-out center mean predicted the offset better than the grand mean: CV R2 0.034 (permutation p 0.0014) for the absolute offset and 0.064 (p 0.0002) for the spectral shape. The effect was largest at 30-45 Hz (CV R2 0.057). The stratified bootstrap 95% CIs include zero (P1 -0.06 to 0.08), so the effect size is not precise. The sampling-rate class did not explain the center effect: with fs class as a covariate, CV R2 was 0.073. Inside the 5 centers with mixed sampling rates, the fs class predicted the offset with CV R2 0.24 (p 0.0002). The 500 Hz and 1000 Hz patients of centers M and P differ by about 1 log10 unit at all frequencies. A flat difference of this size probably comes from the recording system (gain, amplifier or units), but this analysis cannot identify the cause. A norm that permits same-center neighbors hides most of the center effect (CV R2 0.006). The plan was hashed before analysis. The package contains the code, the spectra, the subject table, the hashes and all results.

stereo-electroencephalography · SEEG · spectral power · recording center · recording system · sampling-rate class · normative maps · RAM

Admitted 1 citing publication

References

5
  1. supportsIn 256 RAM SEEG patients, a patient's distant pairs predicted 2–45 Hz spectra better than location-matched pairs from other patients sci:sha256:5c031c53feaa35e57b3be0a9f729b2ce7fdb5746bf94416d68ed7e3bc5bc0e34

    Its other-site location norm was 1.5-3.7% worse; here the addition of a center mean to an other-center norm decreases pair-level error by 2.4%, and the center effect is significant by permutation.

  2. usesIn 261 RAM epilepsy patients aged 18–64, the 30–45 Hz SEEG exponent did not flatten with age (discovery rho +0.08; replication +0.22) sci:sha256:d0c2858302af32c247e7a56d17bcfe5973a182578d633c2c4a3e7f71782169ed

    Uses its subject table (age, sex, site letter, sampling rate) and its segment rule.

  3. usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32

    Uses its archived per-pair bipolar SEEG spectra, accept masks and MNI pair midpoints without change.

  4. usesdoi:10.18112/openneuro.ds004789.v3.1.0

    The archived RAM FR1 spectra are identified as derived from this exact dataset version.

  5. usesdoi:10.18112/openneuro.ds004809.v2.2.0

    The archived RAM catFR1 spectra are identified as derived from this exact dataset version.

Cited by

1 publication

Public catalog entries on Sciscape.