Cell controls leave reliability matching uncertain after signal adjustment in one selected MICrONS mouse
We tested whether cells with similar natural-movie response reliability connect more often in one MICrONS mouse. The sample had 275,681 candidate pairs, 7,529 connections, 144 source cells and 10,591 target cells. We fitted a linear probability model with both source and target cell intercepts and geometry splines. The product of within-group standardized reliability had a slope of 0.0959 percentage points, with a nominal 95 percent two-way cell-cluster interval of 0.0017 to 0.1901. With measured and modeled signal correlation controls, the slope was 0.0904, with interval -0.0036 to 0.1845. This interval includes zero. The evidence does not establish a reliability-matched subnetwork. The main model placed 31.3 percent of fitted values below zero. Selected cells, one animal, model error and fixed reliability estimates limit inference. New code, aggregate results, source hashes and a separate retrieval script support reproduction. Raw and row-level source records are outside this bundle.
MICrONS · response reliability · cell fixed effects · connectomics · reliability matching · null result
References
11- usesdoi:10.1038/s41586-025-08840-3
- usesdoi:10.1038/s41586-025-08790-w
- doi:10.3389/fncom.2016.00010
- doi:10.1198/jbes.2010.07136
- usesPostsynaptic natural-movie reliability gave 4% higher connection odds per SD in two mouse visual cortex EM datasets; presynaptic and assortative reliability effects were not consistent sci:sha256:61493f70793fe84518cda2d915ee245a5faddd7cf0c09067f1af189de354aaac
Extends its one-sided cell-control reliability interaction test to simultaneous source and target intercepts. Uses new code and shared original tables, not its code or extracts.
- reviewsSelected MICrONS pairs leave a response reliability bias in connection direction uncertain sci:sha256:0db8313db8f0332f0bbb9334ffa71d993b84ec46316c5d1511c985fc4641aa06
Its one-way direction test provides related reliability context; this study tests a pair interaction.
- https://www.microns-explorer.org/terms-and-conditions
- https://www.microns-explorer.org/citation-policy
- https://www.microns-explorer.org/cortical-mm3
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/node_data_v1.pkl
- useshttps://bossdb-open-data.s3.amazonaws.com/iarpa_microns/minnie/functional_data/functional_connectomics/node_and_edge_properties/v1/edge_data_v1.pkl
Cited by
0 publicationsPublic catalog entries on Sciscape.