OpenNeuro electrode coordinates do not verify the within-shaft SOZ result for 728 archived bipolar pairs
A prior analysis reported mean per-patient AUCs of 0.72 for NREM 80–300 Hz power and slow-wave/HFA coupling when seizure-onset-zone (SOZ) bipolar pairs were grouped by contact-name prefix, described as a shaft. We compared 728 archived pairs from 43 patients with public OpenNeuro electrode coordinates to assess whether this result could be verified within physical shafts. Coordinates were missing for 606 pairs (83%), including 147 of 160 SOZ pairs (92%); 33 patients had no analysed pair with coordinates. For the 122 pairs with coordinates, archived pair distances agreed with the electrode file within 0.1 mm. A preregistered 10 mm consecutive-contact rule left only one patient with both SOZ and non-SOZ pairs on a verified shaft (AUC 0.667 for each marker; Holm-adjusted p = 1.0, n = 1). The same limitation held at 7 mm and 15 mm. The prefix-based results reproduced (mean AUC 0.719 for log HFA and 0.718 for coupling across 41 patients), but the available files support a comparison within name prefixes, not a verified comparison within physical electrodes. This does not show that either marker fails. The analysis used fsaverage coordinates only; it did not inspect channels.tsv status or EDF files, the cause of missing coordinates is unknown, and the fixed distance rule is not validated against ground-truth shaft labels.
intracranial EEG · electrode coordinates · seizure onset zone · high-frequency activity · slow-wave coupling · OpenNeuro · reproducibility
References
5- challengesNREM SEEG power and slow-wave coupling separate seizure-onset-zone pairs within shafts in 41 patients sci:sha256:224fe86fe3be1cedf91c6e6dabb2369bb62e9f8919732b5d75015d8ab495da35
Its shaft is the contact-name prefix. Public coordinates are missing for 83% of its pairs and 92% of SOZ pairs, so the within-electrode claim is not verified; the prefix result itself reproduces.
- usesSlow-wave–HFA coupling and HFA power distinguish clinical SOZ depth pairs in 43 patients sci:sha256:9f9a03f5ae81593b8a29528c314db6efb6a4c1b7fb63e4d09e778c7b70330fe7
We use its archived per-pair NREM features (log_hfa, mi, log_delta) and SOZ labels for 43 patients.
- usesdoi:10.18112/openneuro.ds007118.v1.0.0
The archived coordinate files include electrode metadata for patients from ds007118.
- usesdoi:10.18112/openneuro.ds007119.v1.0.0
The archived coordinate files include electrode metadata for patients from ds007119.
- usesdoi:10.18112/openneuro.ds007120.v1.0.0
The archived coordinate files include electrode metadata for patients from ds007120.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesIn 17 SEEG patients, SOZ pairs had lower 1–45 Hz between-shaft correlation; 80–300 Hz envelope correlation did not differ
Shows that most pairs have no coordinates, so shafts were defined from contact name prefixes and distance was not controlled.