sciscape Publications
← All publications

An early amplitude gate selected times with higher phase success but lower successful yield in seven SEEG rest pairs under assumed 30 to 70 ms delays and a 2 s offline reference

We tested an early amplitude gate for phase forecasts in seven public SEEG rest pairs. Success required at most 45 degrees of error at every assumed arrival sample from about 30 to 70 ms. The reference used a centered 2 s filter. The reader and gate used past released samples. Mean success increased from 5.61 percent in all times to 7.85 percent in kept times. All seven people had a positive conditional increase. The gate kept 31.39 percent of later candidates. Successful times per candidate fell from 5.61 to 2.48 percent. Mean future-voltage error skill did not increase. No single angle could meet the phase limit at 44.31 percent of kept times. The result describes assumed delays and reused clinical rest data. It does not establish live device performance. The package preserves contact data, source versions and hashes, code, all test decisions, tables, figures, and reproduction instructions.

stereoelectroencephalography · phase estimation · brain-computer interfaces · signal processing · amplitude gate · arrival-time uncertainty · successful yield

Admitted 0 citing publications

References

4
  1. usesAn early amplitude gate increased prediction skill for the future part of a centered theta label at 50 ms in seven SEEG rest records sci:sha256:61788e684e1ae06fcc9bda04cbaef7a95cb53c59c48af85dd5441a6ea6fa3775

    Its early amplitude-gate question and exact known/future label split informed this test. We use different anatomical pairs and time blocks. We test maximum phase error across arrival delays and measure successful yield. We do not claim to reproduce its future-skill increase.

  2. usesTraining for assumed 30 to 70 ms delays did not establish lower theta phase loss in seven SEEG rest recordings sci:sha256:f68a254c558307b78f0b911471055eaeae67c79cb13398a778750d4d37030c16

    Its assumed 30 to 70 ms arrival range motivated the delay scope. Our score requires one angle to meet a 45 degree limit at every sampled arrival. Its average phase-loss comparison is not reproduced.

  3. usesOne phase estimate could not meet a 45 degree limit across unknown 30 to 70 ms delays at 47.8% of test times in seven SEEG rest pairs with a 2 s offline theta filter sci:sha256:fb9a0b3fcf4a2e3076fa5e1c54eda2e595eacebb47c3e94709b83b1531254509

    We use its seven 180 s contact extracts, anatomical pair rule, pinned source manifest, raw-range retrieval and check code, and circular delay bound. We add an early-trained causal reader and amplitude gate, later success and yield scores, and future-voltage checks.

  4. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    OpenNeuro ds006065 v1.0.0 supplies the selected SEEG source data analyzed in this publication.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.