A local phase model reduced mean ripple overlap ranking loss in second sleep records from six patients under the source SEEG mapping
We tested whether local 0.5 to 2 Hz phase can rank supplied ripple overlap labels in another selected sleep record. We used public OpenNeuro ds003498 version 1.1.1. Each electrode pair had a separate model fit to the first selected record. Its second record supplied the test. Comparisons held electrode pair and 28 second time block fixed. Thirty pairs from six patients met the fixed rules. Mean test loss was 0.63314 nats, compared with 0.69315 nats for probability 0.5. This is an 8.66% loss reduction. The paired ranking score was 0.63136. Five patients had positive gains. The exact patient sign-flip p value was 0.0625. The actual score exceeded all 999 fixed block shift control scores. Distal phase gave a mean gain of -0.00341 nats. Population evidence remains uncertain. The SEEG scope assumes that released subject numbers match the depth-only patients in the source study. The target is a supplied detector label. The test does not show a neural cause, clinical benefit, or transfer to a new patient. The package preserves compact inputs, source hashes, code, fixed plans, results, figures, and reproduction instructions. A new public raw rebuild and a second full offline run passed the checks. The checksum check excludes the metadata folder added by AutoSci retrieval.
intracranial EEG · slow-wave phase · high-frequency oscillations · ripple overlap · separate-record validation · paired ranking · sleep · epilepsy
References
4- supersedesA local phase model reduced mean ripple overlap ranking loss in second sleep records from six patients under the source SEEG mapping sci:sha256:d3c69d140a3ef73669a6feda2da37764c28a1343f9e4b36f26bfc5326cfbaa40
This package version corrects the checksum check after AutoSci retrieval. It excludes the service metadata folder. The analysis code, input data, and numerical results are unchanged.
- usesSupplied ripple overlap marks had a higher mean local 0.5 to 2 Hz phase score in 14 sleep records from eight SEEG patients under block timing controls sci:sha256:2dfd019ac33176dad666935802573af7e5e8bb1450e56c59954f24f370241252
We used the compact 50 Hz bipolar voltage, disjoint ripple classes, pinned source metadata, and MIT preparation code. They supplied the input for the separate-record ranking test and the new raw-data audit. The prior phase scores were not model inputs.
- usesdoi:10.18112/openneuro.ds003498.v1.1.1
Source signal and supplied detector labels came from OpenNeuro ds003498 version 1.1.1, pinned by the recorded Git commit and file hashes.
- supportsdoi:10.1038/s41598-017-13064-1
The source study table is used only for the reported depth-only implant scope and its stated mapping limitation.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.