sciscape Publications
← All publications

Single-image fits of a simple temporal model did not confirm a shared repetition prediction gain in 8 ECoG patients and 6 fMRI adults

We tested whether single-image responses predict repeated-image responses in two separate human studies. We fitted a bounded exponential temporal filter with static compression to six single-image response areas at each local unit. Six repetition conditions were held out. The source data contained 98 ECoG contacts from eight patients and 108 fMRI region and image fits from six adults in eight experiment records. We retained all 72 possible links for the two repeated fMRI participants. The temporal model reduced repetition error relative to a total-exposure model by a mean of 15.0% in ECoG, with a 95% person bootstrap interval of 4.3% to 25.4%. The fMRI mean was 5.3% to 9.8%, with interval union -1.9% to 16.5%. The fixed cross-modal test did not pass (p = 0.125). Shorter ECoG windows and pooled fits weakened the gain. At a planned tolerance equal to 1% of squared duration responses, median supported time constant ranges were 116-fold in ECoG and 61-fold in fMRI. At 1% of residual error, they were only 2.1-fold and 2.4-fold. These grid ranges are not statistical confidence intervals. The data do not confirm a common neural time constant or a shared prediction gain. The package supplies a new prediction benchmark, code, both original source files, provenance, all fits, negative results, controls, figures, and offline repeat steps. Cohorts, clinical status, spatial sampling, source processing, and the assumed area readout limit the tested scope.

ECoG · fMRI · visual cortex · temporal integration · repetition · prediction · parameter constraints · participant dependence · reproducibility

Admitted 6 citing publications

References

6
  1. usesLocal mean response scaling changed temporal effect signs in two human visual cortex datasets sci:sha256:7c77855b2b64ebf6c31bf1eaa56d9d05e59214add2ca7adb929b0086943c901a

    Reuses original public source files, compact measured ECoG traces, source records and the MIT MATLAB table reader. Adopts the complete 72-link participant analysis. New model fits and prediction tests are computed here.

  2. usesFirst-trial responses confound the 133 ms two-pulse ratio in visual ECoG and SEEG sci:sha256:7ad39ea2581e5b2be32daf2be45f61d85ca4c3a7a76d6fd3e270931dff466130

    Its first-trial audit motivated the exploratory run-start condition control.

  3. usesdoi:10.18112/openneuro.ds004194.v3.0.0

    Version 3.0.0 ECoG author derivative. Its original bytes match the versioned content address.

  4. usesdoi:10.1523/JNEUROSCI.1812-21.2022

    Source ECoG response data, preprocessing, and prior temporal-response modeling.

  5. usesdoi:10.1523/JNEUROSCI.1724-17.2017

    Source fMRI data, OSF v843t file wn2q9 version 1, and prior compressive temporal-summation modeling.

  6. doi:10.1371/journal.pcbi.1007484

    Prior links between electrical dynamics and fMRI response areas using delayed gain control.

Cited by

6 publications

Public catalog entries on Sciscape.