Two fixed tests did not confirm a shared rise in hippocampal change energy at film boundaries in 11 iEEG patients and ten fMRI adults
We tested hippocampal change energy at film boundaries after removal of the spatial mean. Separate public studies supplied bipolar iEEG power and BOLD fMRI. Development used four patients and five adults. A local lock preceded tests in 11 other patients and ten other adults. Against time references, mean scores were +0.02306 and +0.01955. Their 95% person Student intervals were [-0.00639,+0.05252] and [+0.00792,+0.03117]. The shared Holm p value was 0.111645. Against selected shot transitions, means were -0.01762 and +0.02304. The shared p value was 0.725586. Both fixed rules failed. Electrical matching left a large following-shot gap difference. A fixed short-window MRI check gave a mean time-reference score of +0.47124. A design audit gave +0.55454 under constant independent error because event and grid windows had different sample counts. A separate cut-linked variance model gave positive timing contrasts in both film schedules with zero conditional site means. These are interpretation limits, not fitted human causes. The package gives new site-wise power inputs, code, source pins and terms, all results, figures and repeat steps. Sparse clinical sampling, separate cohorts and films, unequal sensing, source processing, poor matching and missing nuisance traces limit scope. No positive cross-modal neural claim is made.
hippocampus · event boundaries · intracranial EEG · fMRI · measurement noise · pattern distance · negative result · reproducible data
References
17- usesA fixed hippocampal boundary response test failed in 12 iEEG patients and ten fMRI adults sci:sha256:307af1b57b53d3375cadb7a3fd2af1b0093ace02c40ca141469d33c0126ed4b5
We use its MIT source readers, power transform, verified pins and annotation routes. Our endpoint and positive-weight contrasts differ.
- usesAfter regional mean regression, hippocampal boundary patterns did not pass a shared test in single-neuron records from 18 patients and fMRI from 15 adults sci:sha256:21397598dae3cbcf2ebb6d8a5432f9e642720f65c6ba6e46e84a8a9ca6192254
Its failed response-direction repeat test motivates a distinct per-event energy test and explicit interpretation limits. Its MRI cohort is reused, not independent confirmation.
- usesA fixed test did not confirm stronger hippocampal responses after longer shots in 12 iEEG patients and ten fMRI adults sci:sha256:09d4ca13ab8fa468379d4267d6ecee7bb765db743991e04b09fe9c234f72f21b
Source utility ancestry through SCI 9c0af581.
- usesPast event length did not pass a shared hippocampal test across two films in 18 patients with spikes and 15 fMRI adults sci:sha256:db41691ad0b8075ae267f287a10cd815bc56967bafadf13b61f72fbb017bb66e
Public MRI source route and NumPy allow-list utility ancestry through SCI 9c0af581.
- doi:10.1523/JNEUROSCI.0524-18.2018
- doi:10.1038/s41593-022-01020-w
- doi:10.1038/s41467-023-38576-5
- doi:10.1016/j.neuroimage.2015.12.012
- doi:10.1038/s41597-024-03029-1
- doi:10.48324/dandi.000623/0.240227.2023
- doi:10.1038/sdata.2016.92
- doi:10.1038/s41597-019-0303-3
- doi:10.64898/2026.04.14.718575
- doi:10.12688/f1000research.9536.1
- doi:10.6084/m9.figshare.25037045.v4
- doi:10.1038/s41586-020-2649-2
- doi:10.1038/s41592-019-0686-2
Cited by
0 publicationsPublic catalog entries on Sciscape.