Ten-pulse response-label AUC exceeded mean five-pulse subset AUC at 10 to 90 ms in UMCU21 SEEG with agreed binary labels fixed
We tested pulse-count comparisons in one public SEEG record, UMCU21, from OpenNeuro ds004774 v1.0.0. The test used surface stimulation, six depth readout contacts, and 188 cells with two expert labels. With agreed binary labels fixed, 38 disputes permitted 2^38 label vectors. For a fixed absolute voltage score at 10 to 90 ms, the planned ten-versus-first-five AUC difference had exact limits of -0.010253 and +0.064570. The planned mean-subset check averaged all 252 five-pulse AUCs. Its limits were +0.008105 and +0.041217 under a common label vector. Thus, ten pulses exceeded this average for every allowed label choice. Only 64 of 252 subsets had positive lower label limits. The mean-subset result retained a positive lower limit at 20 to 90 ms, but could reverse for N1 alone. These are finite-data sensitivity limits, not confidence intervals or evidence of online interface benefit. The package includes three figures, source epochs and labels, all scores and attained-limit labels, an exact-bound proof, source hashes, code, and replay instructions. All 330 raw epoch ranges and nine source files passed fresh download checks.
evoked potentials · stimulation · AUC · label uncertainty · SEEG
References
4- usesWith agreed labels fixed, source AUC was higher than mean reference AUC for all disputed N1 or P1 labels at 20 to 90 ms in UMCU21 SEEG sci:sha256:a22aad17c85120cbcda451011b2e5b9c5c759e027d62afcc51ad9f61e73d6e65
This study uses the paired midrank AUC method, MIT rank code, and pinned source range audit recipe. It applies the method to pulse counts and extends the code to equal-weight mean AUC over fixed pulse subsets.
- usesTen-pulse means had higher response label AUCs than first pulses for a fixed 10–90 ms absolute score in two SEEG recordings sci:sha256:1dfa7a52fe9acf5f4a7a85e2004bf3a19d22575d694466d89d391e4150e0d226
This study uses the UMCU21 pulse epochs, source expert labels, event maps, and fixed voltage score from this package. It changes the analysis to matched expert cells and exact label bounds for pulse-count comparisons.
- usesdoi:10.18112/openneuro.ds004774.v1.0.0
The analysis uses record UMCU21 from OpenNeuro ds004774 v1.0.0; the cached exact-version record identifies this dataset DOI and CC0 license.
- doi:10.1016/j.jneumeth.2025.110389
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.