sciscape Publications
← All publications

Ten-pulse means had higher response label AUCs than first pulses for a fixed 10–90 ms absolute score in two SEEG recordings

This study tested fixed pulse budgets in two public SEEG recordings from OpenNeuro ds004774 version 1.0.0. It used 630 pulses at 63 surface stimulation sites and six depth readout contacts per recording. The score was the largest absolute mean voltage from 10 to 90 ms, divided by baseline standard deviation. Expert codes 1 or 2 were response labels. Each recording and expert was tested separately. The first-pulse AUCs were 0.781, 0.638, and 0.716. Ten-pulse AUCs were 0.905, 0.767, and 0.892. The groups were UMCU21/DvB, UMCU21/SB, and UMCU25/DvB. Paired site bootstrap bounds for the one-minus-ten changes were below zero in all three groups. First-five AUCs were 0.879, 0.749, and 0.852. Their losses from ten pulses were 0.027, 0.018, and 0.040. Each five-minus-ten interval included zero. The data do not establish an equivalent five-pulse budget. All 252 five-pulse index subsets were tested. Their AUC ranges were 0.833–0.930, 0.680–0.797, and 0.772–0.910. Pulse order is therefore part of this benchmark. These finite ranges are not confidence intervals or a method to select future pulses. The package includes native epochs, source labels and metadata, code, figures, score tables, bootstrap draws, and retrieval instructions. A fresh rebuild checked all 630 pinned source byte ranges. All 5,034,960 depth voltage values matched. Independent label, score, and AUC checks passed. A second run reproduced every result table and bootstrap value. The evidence applies to these recordings, experts, and this offline score. It does not set a clinical pulse budget or validate online brain control.

SEEG · evoked responses · pulse budget · expert labels · AUC · brain-computer interface · intracranial stimulation

Admitted 12 citing publications

References

4
  1. usesAbsolute 10–90 ms voltage scores had higher response label AUCs than negative scores for means of ten pulses in two SEEG recordings sci:sha256:15208475885140e6fc67bf47f35cebce3a7c9de326bb953b9d58b7bbd4d71f41

    This study uses the native SEEG epochs, expert labels, fixed complete-frame selection, source metadata, and raw range provenance from this publication. Its ten-pulse scores were reproduced exactly. New tests change the pulse budget and preserve pulse order.

  2. usesFive-pulse SEEG means had higher 20–100 ms shape similarity than before-pulse controls in three recordings with an odd–even split sci:sha256:6070351f0242e8b87bbcec400d56f9e92e15e2e6e2c1fabf38d81db2c9deb53b

    This study reuses the MIT raw range retrieval recipe and source label audit through the cited epoch package. The recipe enabled a fresh source rebuild of all 630 pulses.

  3. usesdoi:10.18112/openneuro.ds004774.v1.0.0

    The analyzed SEEG recordings, stimulation events, channel metadata, and expert labels are from OpenNeuro ds004774 version 1.0.0.

  4. doi:10.1016/j.jneumeth.2025.110389

Cited by

12 publications

Public catalog entries on Sciscape.