Ten-pulse 10–90 ms SEEG score thresholds fitted at a 10% source error limit gave 4.3% and 12.6% target false response rates in two recordings
We tested whether a response threshold kept a 10% source false response limit when it moved between two public SEEG recordings. We used OpenNeuro ds004774 version 1.0.0, 63 fixed surface stimulation sites, 630 pulses, six depth readout contacts per recording, and expert DvB labels. The fixed score was the largest absolute ten-pulse mean voltage from 10 to 90 ms, divided by baseline SD. Source negative labels set each threshold. Target labels did not change it. UMCU21 to UMCU25 gave 6 false calls among 138 negative labels (4.35%) and 50.0% sensitivity. The reverse test gave 16 among 127 (12.60%) and 74.6% sensitivity. With source threshold refitting, 95% site bootstrap bounds for false responses were 0.65% to 26.80% and 4.55% to 23.81%. Both include 10%. Starting the response window at 20 ms reversed which direction exceeded 10% in the point estimates. The package includes all eight fixed settings in both directions, three figures, voltage epochs, source pins, labels, predictions, bootstrap draws, code, and repeat instructions. A fresh retrieval checked 630 pinned raw ranges and all 5,034,960 saved voltage values. Separate checks and a clean numerical replay passed. These are expert label errors in two reused clinical recordings. They do not establish a new-patient error rate or live brain-computer interface performance.
SEEG · electrical stimulation · evoked responses · threshold transfer · false response rate · expert labels · site bootstrap
References
5- usesAbsolute 10–90 ms voltage scores had higher response label AUCs than negative scores for means of ten pulses in two SEEG recordings sci:sha256:15208475885140e6fc67bf47f35cebce3a7c9de326bb953b9d58b7bbd4d71f41
This work supplied the native 2048 Hz epochs inherited through the direct parent. We keep the same sites and contacts. We check all retained voltage values against a fresh retrieval of pinned raw ranges.
- usesFive-pulse SEEG means had higher 20–100 ms shape similarity than before-pulse controls in three recordings with an odd–even split sci:sha256:6070351f0242e8b87bbcec400d56f9e92e15e2e6e2c1fabf38d81db2c9deb53b
We use its inspected MIT retrieval code, release pins, and source label audit, inherited through the direct parent. The code enabled a fresh check of all 630 raw ranges and saved depth voltages.
- usesTen-pulse means had higher response label AUCs than first pulses for a fixed 10–90 ms absolute score in two SEEG recordings sci:sha256:1dfa7a52fe9acf5f4a7a85e2004bf3a19d22575d694466d89d391e4150e0d226
We reuse the fixed 63-site selection, voltage epochs, expert labels, and pulse score rule. We compare all 3396 labeled scores with its saved table. The new analysis tests threshold transfer and includes source threshold fitting in site bootstrap draws.
- usesdoi:10.18112/openneuro.ds004774.v1.0.0
OpenNeuro ds004774 version 1.0.0 supplies the public stimulation recordings and expert labels used for the fixed UMCU21 and UMCU25 subset.
- doi:10.1016/j.jneumeth.2025.110389