Pulse variance correction gave AUC gains below 0.007 with intervals that included zero for the first five pulses in two SEEG recordings
We tested whether pulse variance correction improves response label ranking with five pulses. We used OpenNeuro ds004774 version 1.0.0. The fixed subset has 630 pulses at 63 surface stimulation sites, with six SEEG readout contacts in each of two recordings. Manual codes 1 and 2 were response labels. The selected data had 566 label entries. Each recording and rater was tested separately. The primary window was 10 to 90 ms. Both energy scores used the same baseline power scale. Correction increased first-five-pulse AUC by 0.002773, 0.002909, and 0.006039. All paired 95% site intervals included zero. Intervals that also resampled readout contacts included zero. Correction reduced the before-pulse energy floor. It did not establish a reliable response-label ranking gain. This result does not prove equal performance. The score uses a known cross-pulse product identity. Its unscaled unbiased expectation requires a common mean and independent zero-mean pulse errors. The normalized ratio has no such proof here. The package preserves native epochs, source metadata and labels, code, bootstrap arrays, four figures, licenses, and reproduction commands. A fresh check verified all 630 pinned raw ranges and all 5,034,960 SEEG voltage values. Independent checks passed. A new-folder run reproduced all saved tables, PNG figures, and bootstrap arrays. The evidence is conditional on these two recordings and source labels. It does not establish a neural source or BCI performance.
evoked responses · pulse variance · SEEG · brain-computer interface · AUC · energy score
References
3- usesAbsolute 10–90 ms voltage scores had higher response label AUCs than negative scores for means of ten pulses in two SEEG recordings sci:sha256:15208475885140e6fc67bf47f35cebce3a7c9de326bb953b9d58b7bbd4d71f41
Its source label audit informed the primary response target, which includes codes 1 and 2, and the secondary target for code 1. The present study tests new energy scores and preserves a separate audit of all finite depth annotation codes.
- usesTen-pulse means had higher response label AUCs than first pulses for a fixed 10–90 ms absolute score in two SEEG recordings sci:sha256:1dfa7a52fe9acf5f4a7a85e2004bf3a19d22575d694466d89d391e4150e0d226
Its package supplied native SEEG epochs, source labels and metadata, pinned raw-range retrieval code, site selection records, and absolute peak scores. These inputs enabled the new paired comparison of mean energy and pulse-variance-corrected energy. A fresh source check verified all raw ranges and voltage values.
- usesdoi:10.18112/openneuro.ds004774.v1.0.0
The analyzed SEEG epochs, labels, metadata, and source event records come from OpenNeuro ds004774 release 1.0.0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.