A fixed vertebrate contrast failed its shared test in 14 SEEG patients and five fMRI adults
We tested a fixed vertebrate versus invertebrate response relation within selected animal groups. Separate public studies supplied human SEEG amplitude and BOLD fMRI. Three patients supplied local development. A code lock preceded reserved tests in 14 other patients and five MRI adults. We used different pictures for two category means, site scales from other categories, and raw cross-half distances. A full category endpoint projection removes norm-only distance structure. One source AlexNet image-distance map was also removed. Mean partial correlations were 0.03972 and 0.19959. Their 95% person Student limits were [-0.04845,0.12788] and [0.04426,0.35492]. Seven of 14 electrical scores and all five MRI scores were positive. The MRI rule passed. The electrical rule did not. The shared positive rule failed, p=0.17419. It required person sign-flip, person Student and whole-category label tests in each modality. Removing insect reversed the clinical mean. MRI single-category deletion means stayed positive. Distinct-image group contrast agreement was uncertain in SEEG. The clinical panel contains only three invertebrate groups, all arthropods. Sparse placement, separate cohorts and images, source order assumptions, untested appearance factors and measurement filters limit inference. No positive neural generalization or causal modality difference was confirmed. The package gives a reusable benchmark, code, source pins and terms, every result, figures and repeat instructions.
human neuroscience · SEEG · fMRI · animal vision · vertebrates · representational geometry · subject dependence · reproducibility
References
10- usesA fixed test did not confirm taxonomic geometry beyond animacy and visual controls in 14 SEEG patients and five fMRI adults sci:sha256:5a567459d8b1c2326517239ed17a59053cffae7954e83f22468ef24abd0042a8
We reuse source pins, category tables, the downloader and reader guidance. We test a fixed within-animal contrast with raw distances and nonanimal scale images.
- A fixed test supported animal transfer from mammals in IT fMRI but not in medial temporal spiking sci:sha256:65383fc899c1578f1078cd16dc1e4b254b65bca0cef644cea52acee50bf5feec
This related study tested mammal-trained transfer to other vertebrates in different spike and MRI studies. We distinguish its scope.
- usesdoi:10.1371/journal.pbio.3003614
We reuse public version-1 depth-electrode response and baseline summaries from OSF muq48.
- usesdoi:10.1038/ncomms15037
This is the original study for the reused Generic Object Decoding MRI data.
- usesdoi:10.1038/sdata.2019.12
This source describes compact MRI processing, region masks, image IDs and features.
- usesdoi:10.5281/zenodo.1742390
This fixed dataset record pins the five compact MRI files. Full hashes match the byte-identical Figshare mirrors.
- usesdoi:10.6084/m9.figshare.7387130.v8
This version pins source image features. We extract the fixed cnn7 subset and check its exact value hashes.
- doi:10.1523/JNEUROSCI.5547-11.2012
- doi:10.1523/JNEUROSCI.2628-20.2021
- doi:10.7554/eLife.82566
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesAt 16 mapped object groups, a fixed SEEG template failed a shared test in 14 other patients and five fMRI adults
We adapt source readers and download helpers and use its raw endpoint norm control.