Mean alpha peak recurrence at the same contact exceeded the shaft exchange expectation in paired 60-second SEEG files from 36 epilepsy patients under CAR
We tested whether alpha spectral peaks recur at the same SEEG contact above exchange within an inferred electrode shaft. We used paired 60-second files from all 36 patients with available paired SEEG records in OpenNeuro ds004100 version 1.1.3. The main rule used common average reference, a fixed log-frequency trend, and an 8 to 13 Hz search band. The peak height threshold was 3 dB. The frequency tolerance was 1 Hz. Mean recurrence was 43.9% at the same contact and 31.7% under exchange. The equal patient mean difference was 12.2 percentage points. The patient bootstrap 95% interval was 7.9 to 17.0 points. The difference was positive in 31 of 36 patients. Ten planned descriptive checks also gave positive mean differences. A fresh rebuild from all 72 byte-verified signal excerpts preserved every primary peak decision and all statistical endpoints. The recording interval is unknown. These results apply to the supplied files and the fixed peak rule. They do not establish neural oscillations, long-term stability, or clinical value. The package includes code, spectra, contact results, statistical draws, source records, and repeat instructions.
SEEG · alpha peaks · spectral recurrence · common average reference · electrode contacts · patient bootstrap · shaft exchange
References
4- usesCommon average reference raises median relative gamma rank agreement in two 60 s SEEG records from each of 36 HUP patients sci:sha256:3f5f9f6ae779730a7bf70359ae9ddc56a5032c2e8abdb97c0cf3c127d6082e74
We used its 36 paired SEEG spectrum files, source metadata, raw byte hashes, and retrieval code for a new alpha peak recurrence study. A fresh raw signal rebuild checked all spectra and reproduced the new statistical endpoints.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The study analyzes paired 60-second SEEG files from the HUP iEEG Epilepsy Dataset, OpenNeuro ds004100 version 1.1.3.
- doi:10.1038/s41593-020-00744-x
- doi:10.1093/cercor%2Fbhad482
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesMean alpha peak recurrence at the same contact exceeded the shaft exchange expectation in paired 60-second SEEG files from 36 epilepsy patients under CAR
The revised package checker excludes the service metadata that AutoSci adds on download. The first checker rejected correct downloads. The analysis, input spectra, results, and scientific report are the same.