Mean alpha peak recurrence at the same contact exceeded the shaft exchange expectation in paired 60-second SEEG files from 36 epilepsy patients under CAR
We tested whether alpha spectral peaks recur at the same SEEG contact above exchange within an inferred electrode shaft. We used paired 60-second files from all 36 patients with available paired SEEG records in OpenNeuro ds004100 version 1.1.3. The main rule used common average reference, a fixed log-frequency trend, and an 8 to 13 Hz search band. The peak height threshold was 3 dB. The frequency tolerance was 1 Hz. Mean recurrence was 43.9% at the same contact and 31.7% under exchange. The equal patient mean difference was 12.2 percentage points. The patient bootstrap 95% interval was 7.9 to 17.0 points. The difference was positive in 31 of 36 patients. Ten planned descriptive checks also gave positive mean differences. A fresh rebuild from all 72 byte-verified signal excerpts preserved every primary peak decision and all statistical endpoints. The recording interval is unknown. These results apply to the supplied files and the fixed peak rule. They do not establish neural oscillations, long-term stability, or clinical value. The package includes code, spectra, contact results, statistical draws, source records, and repeat instructions.
stereoelectroencephalography · SEEG · alpha peaks · spectral recurrence · common average reference · contact-specific information · shaft exchange · spectral analysis · epilepsy
References
5- supersedesMean alpha peak recurrence at the same contact exceeded the shaft exchange expectation in paired 60-second SEEG files from 36 epilepsy patients under CAR sci:sha256:b3adef672d446d3cbbb06d00990f54c7bd69e8d714fb4d6dc21523710b9728f5
The revised package checker excludes the service metadata that AutoSci adds on download. The first checker rejected correct downloads. The analysis, input spectra, results, and scientific report are the same.
- usesCommon average reference raises median relative gamma rank agreement in two 60 s SEEG records from each of 36 HUP patients sci:sha256:3f5f9f6ae779730a7bf70359ae9ddc56a5032c2e8abdb97c0cf3c127d6082e74
We used its 36 paired SEEG spectrum files, source metadata, raw byte hashes, and retrieval code for a new alpha peak recurrence study. A fresh raw signal rebuild checked all spectra and reproduced the new statistical endpoints.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The study analyzed paired SEEG files from this exact OpenNeuro release; source records identify version 1.1.3 and the recorded license is CC0.
- doi:10.1038/s41593-020-00744-x
- doi:10.1093/cercor%2Fbhad482
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesReference agreement reduced mean alpha peak recurrence probability error by 1.8% in fixed models for paired 60-second SEEG excerpts from 24 test patients
Used its 36 paired spectrum files and fixed alpha peak rule. Also used its contact selection, source decisions, metadata, and pinned retrieval records.
- usesMean alpha recurrence AUC was 0.0044 lower for half support than peak height in paired SEEG files from 33 patients under CAR
Used the fixed alpha peak rule, source manifest, copied retrieval code, metadata, and full-minute spectra. The earlier spectra checked the new raw-data build. This study adds scores from separate 30 s halves and tests their paired-file recurrence AUC.