Mean alpha recurrence AUC was 0.0044 lower for half support than peak height in paired SEEG files from 33 patients under CAR
We tested whether support in both 30 s halves ranks alpha peak recurrence better than full-minute peak height. We used the first 60 s in each paired SEEG file from OpenNeuro ds004100, version 1.1.3. The fixed rule used common average reference, a 3 dB peak threshold, and a 1 Hz recurrence tolerance. Of 36 patients, 33 had both recurrent and nonrecurrent candidates and could define an AUC. Their mean AUC was 0.6566 for the smaller support in the two halves and 0.6610 for full-minute height. The mean gain was -0.0044. Its 95% patient bootstrap interval was -0.0546 to 0.0521. These data did not show a gain. They did not establish equal performance. The interval assumes independent patients from a common population. All eight fixed descriptive changes had negative mean gains, with different patient coverage. The package preserves full and half spectra, scores, statistical draws, source hashes, code, and a raw-data retrieval recipe. Independent numerical checks and an offline repeat passed. The biological interval between files is unknown.
alpha peak recurrence · stereoelectroencephalography · SEEG · spectral peaks · Welch power · common average reference · paired files · area under the curve · patient bootstrap · signal processing
References
4- usesMean alpha peak recurrence at the same contact exceeded the shaft exchange expectation in paired 60-second SEEG files from 36 epilepsy patients under CAR sci:sha256:09561fa21b992b384f68f982843f02b820a3b25591b400af778300072dc58a96
Used the fixed alpha peak rule, source manifest, copied retrieval code, metadata, and full-minute spectra. The earlier spectra checked the new raw-data build. This study adds scores from separate 30 s halves and tests their paired-file recurrence AUC.
- usesCommon average reference raises median relative gamma rank agreement in two 60 s SEEG records from each of 36 HUP patients sci:sha256:3f5f9f6ae779730a7bf70359ae9ddc56a5032c2e8abdb97c0cf3c127d6082e74
Used the original public SEEG source selection, contact quality rules, source identity records, and raw excerpt retrieval recipe inherited through the alpha report.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source data and metadata for the analyzed SEEG excerpts; the exact dataset version is recorded as 1.1.3.
- doi:10.1038/s41593-020-00744-x
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.