sciscape Publications
← All publications

A rule that used half of one SEEG monitor's gain change did not establish pulse tracking after contact order reversal in eight patients

We tested whether one SEEG monitor could track pulse responses on other electrode shafts. The sample had eight epilepsy patients and 96 stimulation conditions from public STReEF data. Five early pulses selected each monitor and set response templates. Five later pulses followed a recorded contact order reversal. The rule applied half of the measured monitor gain change to each target template. Mean patient normalized error fell by 3.37 percent from the fixed template. Values from other pulses gave a 3.29 percent reduction. The benefit of correct pulse matching was 0.081 percent of fixed error. Its descriptive 95 percent patient interval was -0.168 to 0.293 percent. Thus this rule did not establish pulse tracking. An added early-only scale comparison had lower error without a test monitor reading. The result concerns retrospective slow-voltage reconstruction in a reused clinical sample. It does not establish a live interface benefit. The package supplies three figures, feature data, frozen fits, pulse-level losses, code, and version-pinned source retrieval. All 960 voltage ranges and 147 metadata files matched their source hashes. Independent loss checks and a numerical replay passed.

SEEG · electrical stimulation · pulse response · signal processing · voltage reconstruction · brain-computer interface · epilepsy · OpenNeuro

Admitted 2 citing publications

References

7
  1. usesA scale from five early pulses reduced full template SEEG error at 20 to 500 ms after contact order reversal in eight people sci:sha256:c50236eb3980bc5de34015c4d5cd7787844c23bfd051cf18a9adcfe20685512d

    Used its MIT metadata selection and range retrieval helpers through the direct input. Adapted its early variation scale for an added reference on the same 16-mode targets. This reference was added after the primary result.

  2. usesA five-pulse test did not establish a cross-shaft noise covariance change after stimulation in eight SEEG patients sci:sha256:ac64ed2ad4f89c67d3e451fc116295b7696f34f36ea9939509de83e2f450d198

    Used the fixed 96-condition sample, contact maps, source receipts, archived coefficients, and five unchanged source modules. Retrieved all pinned voltage ranges again before the new monitor analysis.

  3. usesDonor covariance raised mean 16-mode SEEG response AUC after five local fit pulses at 86 selected sites in eight patients sci:sha256:6c4cced9dadb0e1e3eda59b7313983bcc2e732c773a7d1d9a0363f14681fece4

    Used its nonconstant orthonormal cosine basis and centered feature transform through the unchanged module in the direct input. These functions define the 16-mode voltage space tested here.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Source data used in this analysis: STReEF/OpenNeuro ds005448 version 1.0.0.

  5. doi:10.1111/epi.17528
  6. doi:10.1016/j.ynirp.2025.100274
  7. doi:10.1007/s12021-022-09567-6

Cited by

2 publications

Public catalog entries on Sciscape.