Bipolar channel tables did not match EDF labels in 33 public SEEG files from 29 patients
We tested channel maps in public OpenNeuro ds006254. We checked headers from 33 EDF files from 29 patients. We also checked samples from 99 one-second windows. One other EDF file returned an access error. None of the 5,826 SEEG labels in the channel tables matched an EDF label. All 33 files had different signal and table counts. A simple row map also failed a reverse-pair voltage check. Of 1,482 sampled checks, 1,475 exceeded a conservative quantization bound. This check assumed pair subtraction from the same sampled contacts, equal processing, and no added channel noise. It did not identify the hardware reference. We built a tool that refuses an unmatched channel map. The package contains digital samples, headers, source versions, code, results, and three figures. Two session paths had the same annex key and sampled bytes. This audit supports source clarification before BCI calibration. It does not test a decoder or clinical benefit.
stereo-electroencephalography · SEEG · intracranial EEG · channel mapping · electrode labels · EDF · BIDS · brain-computer interface · signal processing · reproducibility
References
2- usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f
The earlier five-pulse study defines the calibration problem and uses an explicit bipolar construction. This study tests the channel-map input requirement in a separate public dataset. It does not use the earlier voltage data or scores.
- usesdoi:10.18112/openneuro.ds006254.v1.0.0
This audit uses channel tables and pinned EDF byte ranges from OpenNeuro ds006254 version 1.0.0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.