sciscape Publications
← All publications

In stored order, a running mean reduced 70 to 230 ms SEEG forecast error by 4.9 percent against a fixed mean in six people

We tested a running mean on public OpenNeuro ds006065 v1.0.0 data. Each forecast used only earlier pulse responses in stored export order. The test used eight blocks from six people and 359 later responses. The target was baseline-corrected SEEG voltage from 70 to 230 ms after a pulse. The running mean reduced mean squared error by 4.88% against a mean fixed after ten responses. All six person means favored it. The 95% person bootstrap interval was 2.11% to 8.37%. Against a fixed pre-block template with one fitted gain, the reduction was 1.36%. Its interval was -2.02% to 4.80%. Shuffled later pulses gave a mean reduction of 4.74%. Stored order had no clear advantage. Controls before the pulse and within the pre-block data also showed reductions against a fixed mean. A proof shows how independent noise can give this benefit with no neural change. The study supplies a simple response forecast benchmark for brain-computer interfaces. It does not establish neural adaptation, real-time performance, or improved stimulation control. The package preserves compact data, four figures, code, forecast states, exact source hashes, and reproduction instructions. All 16 source files were rebuilt and checked. All 32 numerical result files were reproduced. The study reuses an existing six-person cohort.

SEEG · intracranial EEG · evoked response · sequential prediction · running mean · brain-computer interface · forecast error · pulse response

Admitted 4 citing publications

References

6
  1. usesWith 10 calibration trials, amplitude updates had lower error than waveform replacement at fixed SEEG pairs in six people sci:sha256:5fbf5699f54eed2770f2feed9404402fd27dc4a13216f041c985185e72ab0782

    This publication began the source manifest, pinned source versions, metadata, and original code audit inherited here. Its one-gain forecast method provides a comparison model. Earlier forecast results are not treated as new observations.

  2. usesCross-group tests did not establish SEEG response map change across six people sci:sha256:c1ee3af2654efdf1006112a9bbce8e06fd2be8451b3d580e001e611877e2e45f

    This publication first preserved the compact multi-pair voltage bins used here. It supplied the full-source retrieval method and artifact alignment audit. We rebuilt all 16 input files from pinned public source bytes and checked all 96 arrays.

  3. usesWith 10 calibration pulses, a shared timing update had no clear benefit for late SEEG pulse predictions in six people sci:sha256:7f08802fb2748c137073279385149257362ef3e2297465527b8b1703c87b6161

    We retrieved the exact compact inputs, source metadata, source manifest, source code archive, and retrieval script from this publication. Its fixed timing forecast result helped define the comparison with a fixed template gain. This study uses the same cohort and adds a sequential mean forecast and an order test.

  4. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    Version 1.0.0 is the exact OpenNeuro dataset analyzed; the publication uses its public evoked response exports.

  5. doi:10.1038/s41467-025-59417-7
  6. usesdoi:10.5281/zenodo.14735080

    The original MATLAB archive supplied source timing, trial-count, stimulation-site, and polarity information. It was inspected but not executed and is linked externally.

Cited by

4 publications

Public catalog entries on Sciscape.