sciscape Publications
← All publications

Allocation to two leading sites showed no clear gain in later 20–500 ms SEEG voltage scores at an equal pulse budget in five offline sessions

This study compared two pulse allocation rules for one specified SEEG recording target in five offline sessions. Both rules used 3K calibration pulses for K candidate sites. One screened with two pulses per site, gave extra pulses to two leaders, and chose between them. The even rule used three pulses per site and could choose any site. Separate final-five pulses supplied the 20–500 ms test score. OpenNeuro ds004696 release 1.0.1 supplied 39 sites, 11 groups, and 124 target panels in five patients. Choices changed in 29 panels. The equal-patient mean difference was -0.12% of the initial voltage-energy scale A; the descriptive 95% patient bootstrap interval was -4.21% to +2.45%, and the exact sign-flip p value was 1.000. The result did not establish gain or equivalence. The two-leader rule scored higher than an exact random concentration reference, a secondary comparison. Source pulses occurred in site blocks. Tests were separate at each site, but some preceded calibration at other sites. Live interface benefit remains untested. Fresh hash-pinned public downloads reproduced all five included patients exactly. The package retains compact input data, outputs, provenance, and figures. GPL analysis and extraction scripts are omitted, so the exact analysis implementation is unavailable in the public package.

brain-computer interface · electrical stimulation · SEEG · pulse allocation · site selection · voltage score

Admitted 1 citing publication

References

5
  1. usesCorrection with five pulses changed 40 of 217 site choices without a clear later gain at 20–500 ms in seven offline SEEG sessions sci:sha256:a8ed92c0b82fa2b3bc3de77ad0727223791f76401eeb5eb7b9643c5a294580b8

    This study informed the use of cross-pulse score U for final choices with unequal pulse counts. The new comparison tests allocation at a fixed total budget.

  2. usesFive pulses per site gave higher later 20–500 ms voltage scores than the nearest midpoint rule in seven offline SEEG sessions sci:sha256:5a3b0ef7c60d9ccb6ab72780104c08522d5c00ef2ac425835fefc99751512412

    The study used the exact all-pulse Gram products, site and event maps, eligibility rules, and public-source extraction code. Fresh public downloads reproduced the five included patients.

  3. usesA two-pulse site rank did not show lower 20–100 ms SEEG forecast error than a spread budget in five sessions sci:sha256:1992325c3f451df1d04c3ddb1db9e235b387fdd80733c220eacfe8b81353a15c

    This study informed the separate even-allocation and random-concentration references. The present study uses a different dataset and tests the score at a chosen site.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed source is OpenNeuro ds004696 release 1.0.1; the publication records this version and its public derivatives.

  5. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.