sciscape Publications
← All publications

A two-pulse site rank did not show lower 20–100 ms SEEG forecast error than a spread budget in five sessions

We tested whether two early SEEG responses can assign a fixed calibration budget. The public sample was OpenNeuro ds004457 version 1.0.2. It contained 182 stimulation sites, 15 recording pairs, and 728 test pulses in five sessions. The rank gave four calibration pulses to about half the sites and two to the other sites. A reference spread the same 542-pulse budget as evenly as possible. We scored centered voltage from 20 to 100 ms. The mean patient error reduction against the spread reference was -0.55%. The 95% patient bootstrap interval was -2.73% to +1.64%. The exact sign-flip p value was 0.875. A random two-or-four reference gave a more favorable mean reduction of 5.36%. The result did not establish an allocation gain or equal performance. We provide exact budget formulas and a condition under stable responses and independent pulse errors. We rebuilt all five voltage inputs from pinned public source files. The package preserves code, inputs, source hashes, all decisions, result tables, three figures, and reproduction instructions. This offline replay did not test an actual scout-and-return schedule or an interface outcome.

stereoelectroencephalography · pulse allocation · forecast error · brain interfaces · calibration · budget comparison · human neuroscience

Admitted 5 citing publications

References

4
  1. usesMeans of four pulses reduced normalized 20–100 ms voltage error by 33.3% relative to zero across blocks at five sites in three SEEG sessions with equal site and patient weights sci:sha256:c4185cfbe927379d33a3f62f2891c2344d2f6e0fdfac5c4c289565a6078b5983

    This publication supplied the exact ds004457 voltage bins, metadata, contact rules, and source retrieval and extraction code. We checked inherited hashes and rebuilt all five inputs from public MEF files. The new study tests pulse allocation.

  2. usesAn offline two-pulse site rank did not show lower 20–500 ms SEEG forecast error at a fixed budget in eight sessions sci:sha256:578806530d9c396756538b53e11352e83c900274801f852ef7211403fa594c3c

    We use its two-scout disagreement rank, site-level budget design, and exact random-allocation comparator. The new test uses ds004457 and a two-to-four budget. It adds a same-budget spread reference and the model condition for concentration to beat that reference.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The study analyzes the pinned ds004457 version 1.0.2 source files.

  4. doi:10.1523/JNEUROSCI.1325-22.2023

    Describes the source experiment and ventral temporal cortex responses.

Cited by

5 publications

Public catalog entries on Sciscape.