An offline two-pulse site rank did not show lower 20–500 ms SEEG forecast error at a fixed budget in eight sessions

We tested whether disagreement between two early pulses can assign a fixed SEEG calibration budget. The public sample was OpenNeuro ds004696 version 1.0.1, with eight patient sessions, 86 stimulation sites, and 886 stimulation-to-recording pairs. The rule gave three extra pulses to floor(half the sites) within each patient. It forecast each later pulse with the mean of two or five calibration pulses. The score used centered bipolar voltage from 20 to 500 ms and fixed scout-energy weights. The simulated budget was 298 calibration pulses, versus 430 for all-five calibration. Against the exact random-allocation expectation at the same budget, the mean patient error reduction was 0.72%. The 95% patient bootstrap interval was -1.17% to 2.38%; the exact patient sign-flip p value was 0.477. Six patients had lower error and two had higher error. A planned noise-scaled forecast control had mean gain -0.21%. The data did not establish an allocation benefit or equal performance. We prove the optimal known-noise rank under stable responses, independent pulse noise, and fixed weights. That proof does not establish that two scouts estimate a useful rank. The package includes exact input products, all decisions, result tables, three figures, code, source hashes, and reproduction instructions. Two complete public source derivatives were rebuilt and matched the archive exactly. This is an offline test. It does not establish a prospective schedule, cross-session transfer, or clinical benefit.

stereoelectroencephalography · SEEG · electrical stimulation · calibration · forecast error · brain-computer interfaces

Admitted 10 citing publications

References

5
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    We used all eight corrected exact trial-product files and their chronological pulse sets. We also used its calibration-only noise-scaling rule as a planned descriptive control.

  2. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    We reused the public derivative retrieval and extraction code, source metadata, anatomical pair rules, and same-block reference cancellation analysis. This enabled source rebuilds and the compact fixed-budget benchmark.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source data: OpenNeuro ds004696, version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023
  5. doi:10.1371/journal.pcbi.1011105