An offline two-pulse rule reduced 20–500 ms SEEG map error in two of five people at an equal pulse count
We tested whether two initial SEEG responses can guide a fixed pulse budget for a response map. We used 183 sites and 15 recording pairs from five people in OpenNeuro ds004457, version 1.0.2. The rule assigned two to six pulses per site. The uniform rule assigned four. Each rule used 732 pulses. Two separate later pulses per site gave 366 test pulses. For centered voltage from 20 to 500 ms, the mean error reduction across people was 6.99%. Error fell in two people and rose slightly in three. The median effect was minus 0.39%. The exact two-sided person sign-flip value was 0.50 under a symmetric null effect assumption. The rule reduced mean error by 10.19% relative to random placement of the same unequal counts. These results do not establish a general benefit. The integer rule minimizes a fixed variance score. Its expected-error proof needs stable responses and independent trial noise with known variances. The measured rule uses noisy estimates. Pulse times interleaved across sites, so this was an offline test. We verified 110 public source files and rebuilt all ten input files with identical hashes. The package preserves three figures, code, data, source records, and repeat-run checks. It also marks waveform and pulse-sequence checks added after the main result.
SEEG · pulse allocation · response mapping · electrical stimulation · variance reduction
References
4- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
This study reused the voltage bins, fixed contact selection, source event rules, and extraction code. We rebuilt every input from the original public files and verified identical hashes.
- usesAn offline two-pulse site rank did not show lower 20–500 ms SEEG forecast error at a fixed budget in eight sessions sci:sha256:578806530d9c396756538b53e11352e83c900274801f852ef7211403fa594c3c
This study used the two-pulse allocation question and the exact random-placement comparison. It tested a bounded integer rule against uniform counts in a different public SEEG cohort.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
This is the exact OpenNeuro dataset version used for the five-person analysis.
- usesdoi:10.1523/JNEUROSCI.1325-22.2023
Source study for the recorded temporal and limbic stimulation responses analyzed here.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesA sequential pulse quota gave no clear error gain over random allocation in an offline test of 20 to 500 ms SEEG from eight sessions
Its all-site allocation and timing audit informed the schedule check. We use a different cohort and do not pool its voltage data.
- usesCorrection with four pulses kept all 15 site choices in five offline SEEG sessions from 20 to 500 ms
This study used its five-person voltage-bin panel, source metadata, fixed contact rules, raw file manifest, and extraction code. We excluded its one 4 mA site. Fresh retrieval verified all 110 source files, and fresh extraction matched all ten compact inputs. The new question tests the site choices made from corrected and uncorrected early energy scores.
- usesA 24-pulse screen had a 2.0-point higher mean response fraction in eight-site SEEG tests from five patients when stored responses were assumed to stay fixed
Used the prior equal-budget response-map analysis as context after computing the new results. The report explains that the present endpoint selects one site and audits screen loss. The prior code and result files were not analysis inputs.