A 24-pulse screen had a 2.0-point higher mean response fraction in eight-site SEEG tests from five patients when stored responses were assumed to stay fixed

We tested an early screen for stimulation site selection with public SEEG data from five patients. Each test had eight candidate sites. The rules assumed that stored responses would stay fixed if pulses were omitted or put in a different order. The staged rule used two pulses at each site, then two more at each of four retained sites. Both it and the three-pulse-per-site reference used 24 fit inputs. Their mean later response fractions were 86.72% and 84.68%. The gain was 2.04 percentage points. The descriptive 95% patient bootstrap interval was -0.10 to 4.16 points. The sign flip p value was 0.1875. These data do not establish a gain in the patient population. In one patient, the screen removed the site with the largest measured later response in 76.2% of pools. No pool had all fit pulses before all test pulses across sites. The package has source epochs, code, two figures, all pool results, hashes, and raw retrieval steps. A fresh raw rebuild matched all nine epoch files exactly. The endpoint measures voltage response, with no test of clinical benefit or live interface performance.

stereoelectroencephalography · brain-computer interfaces · electrical stimulation · site selection · pulse allocation · evoked voltage

Admitted 0 citing publications

References

5
  1. usesAn offline two-pulse rule reduced 20–500 ms SEEG map error in two of five people at an equal pulse count sci:sha256:17156e369ce8553f9ba6575f9974e5e079fa4e371b8727bb419af66b22756b94

    Used the prior equal-budget response-map analysis as context after computing the new results. The report explains that the present endpoint selects one site and audits screen loss. The prior code and result files were not analysis inputs.

  2. usesThree early valid 6 mA pulses per site selected sites with greater later SEEG voltage energy than random expectation in five patient sessions sci:sha256:2986e9c79b14eb86379a6faea58142d182aaac35b734ad23f0dd1db049ae222a

    Used nine SEEG epoch files, source BIDS metadata, hash manifests, MEF channel information, and the retrieval and extraction code. A fresh raw rebuild matched all nine files. The new analysis tests site selection at an equal fit pulse count.

  3. usesFour pulses gave better mean response ranks than one pulse in five offline bipolar SEEG tests sci:sha256:c9015b4b89ceffc195f0e36e740e7eae7d03e41d8ed41a831cef61e3e6bd2754

    Used the prior pulse-count and response-rank result to frame the site-selection question before the local plan. Its result files were not analysis inputs.

  4. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The analysis used nine bipolar epoch files and source metadata from OpenNeuro ds004457 version 1.0.2.