Three-pulse RMS bounds gave mean coverage of 72.2 percent for later SEEG pulses and 38.1 percent for five-pulse sets at 20–500 ms in eight sessions

We tested fixed RMS forecast error bounds in public SEEG data from OpenNeuro ds004696 version 1.0.1. The test used eight patient sessions, 86 stimulation sites, and 886 stimulation-to-readout pairs. At each site, two early pulses set the forecast and scale. The next three set a maximum error bound across all selected bipolar readouts. The final five good source pulses tested the same bound. Voltage was centered within 20 to 500 ms after each pulse. With equal patient weights, coverage of all selected readouts was 72.2 percent for one later pulse (95 percent patient bootstrap interval 64.9 to 77.6) and 38.1 percent for all five later pulses (25.1 to 49.1). Separate readout bounds covered all readouts on only 17.0 percent of later pulses. The joint rule allowed larger RMS error; it did not change the forecast. With distinct exchangeable calibration and future scores conditional on training, the maximum of m calibration scores covers H future scores with probability m/(m+H). This gives references of 75 and 37.5 percent here. The data do not prove exchangeability or online coverage. We rebuilt all eight public processed derivatives with exact array matches and checked 44 public metadata files. The package preserves code, source hashes, exact data products, a fixed analysis record, result tables, three figures, rank checks, and reproduction instructions. The result shows why a brain-computer interface coverage claim must state its readout set and future pulse count.

stereoelectroencephalography · conformal prediction · forecast error · coverage · electrical stimulation · brain-computer interface

Admitted 5 citing publications

References

5
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This work uses the original bipolar product extraction method and archived MATLAB source documentation. They define the eligible readouts, source reference operations, and exact fixed-window waveform product representation.

  2. usesAn offline two-pulse site rank did not show lower 20–500 ms SEEG forecast error at a fixed budget in eight sessions sci:sha256:578806530d9c396756538b53e11352e83c900274801f852ef7211403fa594c3c

    This test uses the unchanged 24 patient files, corrected chronological pulse maps, exact Gram products, source metadata, and retrieval code. The new outcome is fixed forecast bound coverage across readouts and future pulses.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses public processed derivatives and good-channel and good-pulse labels from OpenNeuro ds004696 version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023
  5. doi:10.1080/01621459.2017.1307116