SEEG bands with fitted shapes had 6.8% lower normalized half-width than constant bands on average for 20–500 ms responses at 86 sites in eight patients
A band must contain every stored sample to cover a complete SEEG response. We compared constant bands with bands shaped by voltage variation in the first five pulses. The test used 440 later pulses at 86 fixed readouts in eight epilepsy patients. The window was 20–500 ms after stimulation. Other patients supplied calibration limits. The mean patient change in normalized half-width was -6.76%. Whole-waveform coverage was 89.97% for shaped bands and 87.03% for constant bands. Four patients had shaped-band coverage below the 90% target. A patient bootstrap with donor limits refitted gave a descriptive 95% width-change range of -28.61% to 6.87%. Shaped bands were wider in the pre-stimulus control. The package preserves exact voltage windows, fitted models, scores, figures, and source retrieval code. This is an offline study in a reused cohort. It gives no clinical coverage guarantee.
stereoelectroencephalography · conformal prediction · simultaneous bands · electrical stimulation · signal processing · whole-waveform coverage
References
7- usesPast pulse updates reduced normalized 20–500 ms SEEG forecast error versus fixed five-pulse templates at 86 selected sites in eight epilepsy sessions sci:sha256:fd07147e53abc31f50ad87cee1d777a9d91b45b3d2a172703485899005f00530
This publication supplied the exact 1,042 retained voltage windows and their pulse tables. Its retrieval code rebuilt all eight processed public source files.
- usesFive calibration pulses gave mean later signed template AUC of 0.939 compared with 0.859 for one pulse in eight SEEG sessions sci:sha256:1d2aa103275ad7400befec4c899740ede8f2eb59a09897bdc3f4d4e190e54418
This study kept its five-pulse readout choices at 86 stimulation sites. No new readout search used calibration or test waveforms.
- usesSite block pooling increased three-pulse SEEG coverage and mean bound score at 20–500 ms in eight patients sci:sha256:7a7e1f9b8a8c02c7fc50f2dc2d6d7a003ddc84cbfc7efa46c1e45c3bf96331d7
Its pooled calibration study motivated donor patient limits and careful unit counts. This study refitted donor limits during patient resampling. The endpoint and pulse split differ.
- usesThree-pulse RMS bounds gave mean coverage of 72.2 percent for later SEEG pulses and 38.1 percent for five-pulse sets at 20–500 ms in eight sessions sci:sha256:8e1cf558fd390a788187427bad722e0296b418b595298fe525f54511fe417f43
Its RMS limits motivated an explicit coverage endpoint. This study instead tested every voltage sample in a response. Both studies share the same patients.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis uses the exact processed voltage windows and pulse tables from OpenNeuro ds004696 version 1.0.1.
- doi:10.1523/JNEUROSCI.2201-22.2023
Source experiment and data collection for the HAPwave recordings.
- doi:10.1371/journal.pcbi.1011105
Source CRP processing method documented for the processed voltage derivatives.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesStudent t limits scored worse than normal limits for centered SEEG voltage at 86 selected sites after five fit pulses
We read this simultaneous waveform band study before the local plan. It supplied context for whole response coverage. We used a different fixed five-pulse fit and did not reuse its band calibration.
- usesFour local pulse scores gave a 2.3 percent higher mean upper limit score than donor scores for 20 to 500 ms SEEG responses at an 80 percent target in eight patients
This study uses the exact 16 retained pulse data files, the fixed early readout choices, the response scale code, and the source retrieval recipe. It makes a new local versus donor calibration comparison in the same cohort.