sciscape Publications
← All publications

Duration and gap response orders did not pass a shared positive test in eight ECoG patients and six fMRI adults

We tested whether visual areas with a larger relative response to long images also retain more response when two brief images have a short gap. Separate public human studies supplied surface ECoG from eight patients and BOLD fMRI from six other adults. Four distinct condition means defined two gain-invariant contrasts. We computed their spatial Kendall rank agreement within each person. The fixed shared positive rule failed. Mean tau was -0.0583 in ECoG, with a 95% person t interval of -0.7086 to +0.5919. The fMRI mean ranged from -0.2222 to -0.0111 over all 72 possible links between repeated records. Its t interval union was -0.7045 to +0.4374. The shared one-sided sign-flip probability was 0.921875. Controls changed signs and retained broad uncertainty. Electrical gap-response orders repeated poorly between trial halves. A later check of positive source estimates and matched area coverage did not replace the failed test. The result does not confirm the proposed spatial surrogate across modalities. It also does not establish independent biological processes or causality. The package supplies permitted compact inputs, source versions and terms, fixed and later plans, all results, code, figures and repeat instructions.

visual cortex · ECoG · fMRI · adaptation · temporal summation · rank agreement · negative result · reproducibility

Admitted 1 citing publication

References

8
  1. usesdoi:10.1523/JNEUROSCI.1724-17.2017

    Source fMRI study and its public response estimates.

  2. usesdoi:10.1523/JNEUROSCI.1812-21.2022

    Source ECoG study and processing design.

  3. usesdoi:10.18112/openneuro.ds004194.v3.0.0

    Version-specific source for author-processed electrical epochs.

  4. doi:10.1371/journal.pcbi.1012161

    Prior work on transient-sustained responses and adaptation across visual areas.

  5. usesArea profiles from three ECoG patients did not improve a fixed forecast in five ECoG patients and six fMRI adults sci:sha256:776a01534632eefed41292a4a875415bc6e1284a07203102214dd1e4e00545a3

    We reuse its verified permitted compact trial inputs, MRI source bytes, attributed processing and source-rebuild helpers. We test a new endpoint.

  6. Fixed recovery tests did not show a shared model violation in eight ECoG patients and six fMRI adults sci:sha256:a897f45ddd7b7f39f0ff91676d8367575836148c09a055ef11f9bd6f4a39f49e

    Prior corrected trial benchmark and recovery tests, in the source lineage.

  7. A fixed ECoG curve had higher mean test error than a line in log gap after calibration at two gaps in five ECoG patients and six fMRI adults sci:sha256:1b54a2029c803d57e291faaebcbc2e6ca96e630c89f77e272f4597a6f351c6b7

    Prior fixed gap-curve transfer test in the same studies.

  8. usesLocal mean response scaling changed temporal effect signs in two human visual cortex datasets sci:sha256:7c77855b2b64ebf6c31bf1eaa56d9d05e59214add2ca7adb929b0086943c901a

    Original compact selection and MIT MATLAB-table reader inherited through the direct SCI source.

Cited by

1 publication

Public catalog entries on Sciscape.