In 8 SEEG subjects, an SPRT used fewer windows and errors than fixed-N, but exceeded nominal error in 5 (p = 0.086)
A sequential probability ratio test (SPRT) can stop a brain-computer interface (BCI) after repeated attempts when accumulated log-likelihood evidence crosses a threshold. We tested whether an SPRT calibrated on trials 1–100 kept a nominal 0.05 error rate on later trials in an offline cued SEEG key-press task. We used archived high-gamma (70–150 Hz) and beta (13–30 Hz) bipolar log-power features from 8 subjects in OpenNeuro ds004473 v1.0.2. A shrinkage LDA decoder and a Gaussian log-likelihood model were fitted using calibration trials; the SPRT was evaluated on trials 101 onward, with at most 20 windows. Mean realized error was 0.046 above nominal, with error above 0.05 in 5 of 8 subjects; the exact one-sided sign-flip test was not significant (p = 0.086). Mean miss rate was 0.148 and mean false-alarm rate was 0.043. Against a fixed-N rule designed for the same nominal error, the SPRT had lower mean error (difference −0.027, p = 0.031) and used fewer windows (difference −1.99, p = 0.016). Shuffling test order did not change error (p = 0.34). These results suggest that the SPRT was more efficient than fixed-N in this dataset, but its nominal error rate was not a reliable guarantee after calibration. The study was offline and used one cued task, one session, 8 epilepsy patients, one decoder, windows from separate trials about 7 s apart, overlapping sequences, and forced decisions at a 20-window cap or end of data. The primary test was not significant; secondary tests were not corrected.
sequential probability ratio test · brain-computer interface · stereo-EEG · SEEG · shrinkage LDA · error rate · calibration · OpenNeuro
References
4- usesBeta power increased later-trial SEEG key-press AUC in 6 of 8 subjects sci:sha256:b76113878b22b13b8fce6b4b57cf321bb22ce16b618b55ae02c2ef42b972f816
Archived ds004473 HG and beta bipolar feature files used as input; SHA-256 values match.
- supersedesIn eight SEEG subjects, an SPRT reduced errors and windows versus fixed-N stopping but exceeded its nominal 0.05 error in five sci:sha256:943ecb7fb32b46c133aead63da503273551820f2e023450a55cedca11dc08ea5
Same analysis and files. The title is corrected: the primary test did not reject the nominal 0.05 error (p = 0.086).
- supportsSEEG decoder margins showed lag-1 dependence, but fixed-threshold errors did not cluster sci:sha256:c9f752258ec6a22136bacdb1ae094a7560f4b7ea97577dcc54a65bd3a5055e90
Shuffled-order control (S2): removing serial order did not change SPRT error (p = 0.34), which agrees with its finding that errors are not clustered in time.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
The archived feature files are documented as derived from OpenNeuro ds004473 v1.0.2, the source dataset for this analysis.