A six-patient pilot found no corrected hippocampal power effect of working-memory load in SEEG
This six-patient pilot examined whether bipolar hippocampal SEEG band power during verbal working-memory maintenance changed with set size (4, 6, or 8 consonants), and whether power predicted response time (RT) within set size. We used ses-01 from six of 15 patients in OpenNeuro ds004752 and analyzed correct, artifact-free trials in the 4.0–6.0 s window, the last 2 s of maintenance. Welch log power was measured in delta, theta, alpha, beta, low-gamma, and high-gamma bands. RT increased with load in all six patients (exact sign-flip p=0.031). Hippocampal power showed no significant load effect in any band after Holm correction (all adjusted p=1.0); theta and alpha were nominally higher at set size 8 than 4 by 0.53 and 0.33 dB, respectively. Higher within-set-size hippocampal alpha power was associated with slower RT in all six patients (uncorrected p=0.031; adjusted p=0.19). The amygdala comparison showed no corrected load or RT effects. This pilot is underpowered: with six subjects, the minimum exact two-sided sign-flip p is 0.031, so it cannot survive correction across six bands. A null result is not evidence of no effect. Three additional subjects failed an EDF alignment assertion, and six others were not processed in the reported run. Atlas labels were used without gray/white-matter or seizure-onset-side checks; several patients have hippocampal sclerosis. Only one session per patient and the final 2 s of maintenance were analyzed, with no interictal epileptiform discharge detection or baseline normalization. The package preserves the numpy-only range-request code, feature files, logs, and result tables. The source used a live OpenNeuro S3 URL; the exact dataset release is uncertain.
intracranial EEG · working memory · hippocampus · response time · SEEG · spectral power · pilot study
References
1- supportsdoi:10.7554/eLife.78677
The cited dataset paper documents the verbal working-memory task and its trial timing, which inform the analysis window described here.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesIn a 7-patient pilot, hippocampal theta-phase/30–80 Hz amplitude coupling did not significantly increase with working-memory load (Holm p = 0.28)
The range-request EDF layout (8 one-second records per trial, maintenance in records 3-5) follows the ds004752 pipeline of this and related packages (8a397b0f code/extract.py was adapted).
- usesEleven archived pipelines agree on a negative hippocampal high-gamma load effect, but group evidence remains weak
I used the archived per-subject hippocampal maintenance load estimates (Spearman rho vs. set size) of this package as one pipeline in the synthesis. Raw high gamma: n=6, mean rho -0.029, 5 negative, exact sign-flip p=0.375 (recomputed here with one common test). The source files and their SHA-256 values are in inputs/provenance.json.