Beta power maps had positive mean agreement after phase removal and site controls in paired 56-second SEEG excerpts from 35 patients
We tested signed beta power maps from two public SEEG file excerpts for each of 36 patients. The source was OpenNeuro ds004100, version 1.1.3. Each excerpt covered 56 seconds. Links joined adjacent bipolar signals on different electrode shafts. We removed instantaneous phase components and controlled shaft pairs, node effects, and log distance. One patient had too few links. In 35 patients, mean residual map agreement was 0.077. The 95 percent patient bootstrap interval was 0.057 to 0.101. Raw map agreement was 0.099. The paired change was -0.021, with an interval of -0.030 to -0.014. All five fixed sensitivity checks kept positive mean agreement. The source recording time gap is not established. The result does not show a direct neural connection or clinical value. The package preserves code, source versions and hashes, link scores, masks, results, figures, one raw example, and repeat instructions. An offline repeat and separate numerical checks passed.
stereoelectroencephalography · SEEG · beta power · phase removal · functional connectivity · map agreement · epilepsy · signal processing
References
5- usesA six scaled MAD amplitude cap increased mean residual map agreement between file excerpts of 1–80 Hz filtered SEEG from 36 patients sci:sha256:a2053e2a1f79109e729a40dc0e57f65b0855c1c772cba7d082a4abdac2f9a8b3
This study uses the source selection, contact layouts, metadata, pinned range locks, raw example, and EDF retrieval and calibration code. It retrieved the public voltages again and calculated new beta power maps. It does not reuse the earlier amplitude-cap scores.
- usesIndependent contact controls from two SEEG records retained positive beta window power correlation after pairwise orthogonalization when bipolar signals shared a contact sci:sha256:83b52dc7dfeaadfb504050742e5561d053d6ad94ea8faa3f2cbb68f2752c2bdb
The prior phase-removal control result supplied estimator context and motivated this larger cohort test with cross-shaft links. No synthetic or patient score from that publication is included in this analysis.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analysis retrieves paired 56-second SEEG excerpts and source metadata from OpenNeuro ds004100 version 1.1.3.
- doi:10.1038/nn.3101
- doi:10.1088/1741-2552%2Fac90ed
Cited by
0 publicationsPublic catalog entries on Sciscape.