A gate based on past voltage raised 4–8 versus 4–10 Hz phase agreement within 45 degrees by 1.73 percentage points in seven SEEG rest records
We tested whether a gate based on past voltage selects later phase targets that agree across theta band definitions. We used seven public SEEG rest records from OpenNeuro ds006065 version 1.0.0. Each record supplied four selected bipolar pairs. A fixed amplitude threshold used early data and a 500 ms past history. Targets were 50 ms later. Centered 2 s filters defined 4–8 and 4–10 Hz phase. Mean agreement within 45 degrees rose from 83.64% at all read points to 85.37% at gated points. The gain was 1.73 percentage points. The gate retained 26.09% of read points. A descriptive person bootstrap gave a 95% interval of 0.61 to 2.84 points. The gate reduced agreement for the planned 5–9 versus 4–10 Hz comparison. Changing the reference to 4–8 Hz changed 16.96% of fixed learned-command success labels. Mean success changed from 51.28% to 50.55%. The package preserves input voltage, models, source hashes, code, results, checks, and four figures. The records and models were reused. These results measure sensitivity to phase definitions. They do not establish a true neural phase or stimulation benefit.
SEEG · neural phase · theta rhythm · signal processing · phase agreement · amplitude gate · brain interface · offline replay
References
2- usesA fixed learned model raised the share of commands within 45 degrees of target phase from 39.79 to 51.28 percent in offline 50 ms SEEG replay of seven rest records sci:sha256:f95e54eb370bc2e0e49af090e06dc6d39029b2a4542255ccea2520190080d0a9
This study uses its preserved SEEG voltage arrays, early contact selection, fixed phase models, and native command rules. All 224 command streams match exactly. We test new phase band definitions and a past-amplitude gate.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
The analysis uses the preserved SEEG voltage arrays from OpenNeuro ds006065, version 1.0.0.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesThree references gave 4.58 percentage points less joint 45-degree agreement than one for nominal 50 ms forecasts with a fixed gate in 36 SEEG patients
Uses the prior two-band gate result as scientific context for phase-reference agreement and the need to report the full opportunity denominator. The new study uses frozen forecast vector lengths and three filter spans on ds004100. It reuses no code or samples from the seven-record study.
- usesPast amplitude gates changed mean 4–8 versus 4–10 Hz phase agreement by -0.56 percentage points in first files from 36 SEEG patients
This study uses the past amplitude gate model and the offline phase band comparisons. It tests the method in a different public SEEG cohort and adds a frozen threshold test in a second file.