sciscape Publications
← All publications

A fixed learned model raised the share of commands within 45 degrees of target phase from 39.79 to 51.28 percent in offline 50 ms SEEG replay of seven rest records

A fixed learned phase model gave better command timing than a calibrated oscillator in seven public SEEG rest records. We reused fixed models and tested native-sample replay with a 50 ms delivery delay and a 100 ms minimum command interval. The mean share of accepted commands within 45 degrees of the requested phase rose from 39.79 to 51.28 percent. All seven people showed an increase. The learned model reached 45.47 percent of offline reference crossings within 20 ms, compared with 38.07 percent for the oscillator. A fixed amplitude gate raised phase accuracy to 61.26 percent, but crossing coverage fell to 14.77 percent. A separate Gaussian noise control gave 40.49 percent phase accuracy with a learned model. The centered offline label contains past and future samples. This control shows that accuracy above the uniform-phase rate does not prove prediction of future neural voltage. The study reuses the same sessions as the parent analysis. It does not test stimulation effects or device performance. The package preserves selected public voltage, fixed fits, command indices, results, four figures, source code, and reproduction instructions. Fresh checks verified all seven full source hashes and exact voltage extraction.

stereoelectroencephalography · SEEG · theta phase · phase estimation · closed-loop timing · ridge regression · offline reference · command coverage

Admitted 8 citing publications

References

7
  1. usesA 500 ms past voltage sum gave a 63.26 degree error for centered theta phase 50 ms ahead in seven SEEG rest records sci:sha256:678ac0e1b4e8d00b5e72eb22a8e9bbbfc9c4bd67c224a77925cb4cba677fc26f

    We used its analysis of overlap between past voltage and centered phase labels to design and interpret the separate noise command control.

  2. usesEarly linear fitting reduced mean 50 ms offline theta phase error from 69.52 to 57.75 degrees in seven SEEG rest recordings sci:sha256:6e0d73f3cfa87fcbac3f6dd9697937e67dc539c31c7ddffb19140640d26f1405

    We used the seven selected voltage files, 84 fixed 50 ms models, phase reference code, and archived forecasts. These files fixed the input and models for native-sample command replay.

  3. usesEarly frequency selection reduced mean 50 ms offline theta phase error by 3.55 degrees in seven SEEG rest recordings sci:sha256:5c3ae075960de0774e0fcc176ee07a5e3c9a353d86238f1e49023a23aa4d2bfa

    We used the early SEEG pair selection and pinned source retrieval method inherited through the parent publication. They define the public inputs and source checks.

  4. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    Source of the seven rest records and selected SEEG voltage used in the replay.

  5. doi:10.1038/s41467-025-59417-7
  6. doi:10.1038/s41598-021-97560-5
  7. doi:10.7554/eLife.68803

Cited by

8 publications

Public catalog entries on Sciscape.