A correction from one SEEG pair increased mean 20–500 ms error over scaled templates at other shafts in eight sessions
We tested whether one observed SEEG pair could improve voltage reconstruction at other electrode shafts. We used public OpenNeuro ds004696 data from eight epilepsy patient sessions. Five early pulses fixed the monitor, template, and linear correction. Five later pulses tested each site. The primary test included 83 sites and 669 target pairs in the 20–500 ms window. The correction increased mean patient error by 2.07% over noise-scaled templates. The descriptive 95% patient bootstrap interval for this increase was 0.48% to 4.69%. Error increased in seven of eight patients. Correct pulse alignment had no mean benefit over a wrong-pulse control with the same stimulation contact order. These results limit this fixed correction after short calibration. They do not establish a limit for all sparse SEEG methods. The package contains exact joint voltage products, source hashes, code, four figures, results, and repeat instructions. The test uses complete simultaneous waveforms. It does not test prediction before stimulation or clinical control.
stereo-EEG · SEEG · single-pulse stimulation · voltage reconstruction · sparse recording · linear correction · limbic system · patient bootstrap
References
5- usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a
This work supplies the scaled template baseline, source metadata, retrieval code, and within-pair audit data.
- usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f
This work supplies the adjacent bipolar pair rules and the first-five and final-five pulse split.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analyzed source was OpenNeuro ds004696 version 1.0.1, pinned to the Git commit recorded in the publication.
- doi:10.1523/JNEUROSCI.2201-22.2023
- doi:10.1371/journal.pcbi.1011105
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesFive later pulses did not establish higher correlation of signed template strengths across shafts after stimulation in eight SEEG sessions
The preserved bin-mean pulse traces, native Gram products, event mappings, metadata, and extraction code came from this publication. They supplied all response data for the new signed-strength test.