The measured mean rate of consecutive large SEEG forecast errors increased by 0.82 percentage points after pulses in eight people
We tested the order of large errors in a fixed SEEG waveform forecast. We compared windows before and after stimulation. We used OpenNeuro ds004696 version 1.0.1. The study had eight people, 317 conditions, and 1,933 later pulses. A forecast used the first five pulses. We marked the largest third of later errors, rounded up, in each series. The main windows were 20 to 500 ms after each pulse and 500 to 20 ms before it. The mean rate difference was 0.82 percentage points. The 95% person bootstrap interval was -0.21 to 1.98 points. The joint pulse order reference gave a two sided p value of 0.0893. Five of eight people had a positive difference. The interval includes zero. These data do not show a clear rise above the before pulse comparison. They also do not establish independent errors. All seven planned secondary differences had intervals that included zero. The package gives an exact order reference for fixed flag counts. It includes three figures, compact data, code, source hashes, and retrieval steps. A fresh rebuild from 64 source channels matched all five inherited data files. A separate numerical run matched all eight result files.
SEEG · intracranial EEG · electrical stimulation · waveform forecasting · forecast error · error order · pulse sequences · exchangeability · brain computer interface · bootstrap
References
4- usesThe mean ratio of consecutive to arbitrary squared SEEG waveform distances was 0.992 at 20–500 ms in eight patients sci:sha256:7772d57bfdee850ed680e7353c67d8ecc95969cd51d402613157a1df8cf0e9fb
This study uses its question about pulse order as prior context. That study measured mean distances between consecutive waveforms. This study measures consecutive large forecast error flags. The cohorts and scores differ. This is not an independent replication from new people.
- usesMean rates of shared large errors in fixed SEEG waveform forecasts exceeded an independent pulse reference before and after pulses in eight people sci:sha256:450829ea4a2474fe15175fd53492702c0ade3f9d8500b65fe074084d20dbf994
This study uses its metadata cohort, five compact data files, and extraction and retrieval code. A fresh source rebuild matched all five input files. The new test concerns consecutive pulse errors. The parent concerns shared errors across readouts on the same pulse. The people are reused.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
This exact OpenNeuro release supplies the SEEG cohort and source recordings analyzed in the study.
- supportsdoi:10.1523/JNEUROSCI.2201-22.2023
This source study describes the eight-person epilepsy cohort and limbic stimulation represented in the dataset.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.