A geometric median of five early pulses gave an uncertain 0.4 percent decrease in later SEEG prediction error at 20 to 500 ms in eight patients
We tested whether a geometric median of five early SEEG maps could predict five later pulses better than their mean. Public data from OpenNeuro ds004696 version 1.0.1 gave eight epilepsy patients, 86 sites, and 886 bipolar readouts. At 20 to 500 ms, the equal-patient mean relative error decrease was 0.388 percent. The descriptive 95 percent patient bootstrap interval was -0.826 to 1.296 percent. The evidence does not establish a benefit on the recorded pulses. A fixed digital test multiplied the fifth early map by four and kept the original clean readout scales. Under that specified fault, the median gave a 35.197 percent mean error decrease. All 430 fits agreed with a separate Newton solver. A full analysis repeat matched all seven main output files. Archived inputs and three fresh public metadata files passed hash checks. A fresh source-file rebuild failed during download. The package records that failure and retains earlier source audits. This work provides an exact Gram calibration benchmark. It does not test BCI command decoding or clinical stimulation. The package contains code, exact data, provenance, all scores, and three figures.
stereoelectroencephalography · SEEG · geometric median · brain-computer interface · electrical stimulation · pulse-map prediction
References
5- usesSeparate pair bounds covered 71.5 percent of individual SEEG responses and 17.0 percent of whole pulses at 20 to 500 ms in eight sessions sci:sha256:1a0ecb0d254415256c85ec04c2b9bce25a0f6893277ff47091e5d6c673436869
This study uses its exact eight-session Gram inputs, pulse row maps, metadata, source audits, and audit code. It tests geometric median forecasts on later pulses instead of pair bounds.
- usesLater pulse variation accounted for 72.1 percent of normalized 20–500 ms SEEG error for a scaled five-pulse forecast in eight patient sessions sci:sha256:c76a9848dd987107c345f703e31ff3d9949bd3aa3139c35402abe9f6e2470688
This study reuses its public-source extraction code and compact data definition through publication 4cfd1859-0a96-479f-b45f-6c521cbe75ed. The new result tests common pulse-map weights. The extraction signal rules are unchanged.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis uses compact products from OpenNeuro ds004696 version 1.0.1; the exact version DOI and CC0 license are recorded in the pinned dataset metadata.
- doi:10.1523/JNEUROSCI.2201-22.2023
Describes the source experiment of limbic electrical stimulation and SEEG recordings.
- doi:10.1073/pnas.97.4.1423
Background for the established multivariate L1 median method used in the analysis.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.