Later pulse variation accounted for 72.1 percent of normalized 20–500 ms SEEG error for a scaled five-pulse forecast in eight patient sessions

We tested how much fixed response forecast error came from differences between later stimulation pulses. Public SEEG data from OpenNeuro ds004696 provided eight patient sessions, 86 stimulation sites, and 886 stimulation-to-readout pairs. The forecast used a scaled mean of five early pulses. Testing used five later pulses at each site. Within-test pulse variation accounted for 72.1 percent of normalized 20–500 ms square voltage error. The descriptive 95 percent patient bootstrap interval was 69.6 to 74.5 percent. The observed error split is exact and needs no independent-noise assumption. A five-pulse correction gave a noise-to-error ratio of 90.1 percent under a stable mean and independent test deviations. Those assumptions were not established. The raw voltage variation share was 66.0 percent. All eight public source files were checked. Their compact arrays and tables matched the archived inputs exactly. A fresh analysis reproduced all six result files. The package contains a proof, reusable code, compact data, all scores, and three figures. The result applies to fixed centered waveforms in these selected epilepsy sessions. It does not establish a biological noise floor or functional brain control.

stereoelectroencephalography · electrical stimulation · evoked potentials · forecast error · pulse variation · noise estimation · brain-computer interfaces · reproducibility

Admitted 10 citing publications

References

4
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    We reused its five-pulse scaled forecast, selected pairs, and exact pulse products. We reproduced 288 patient forecast-loss comparisons. The new result splits its remaining single-pulse error into test-pulse variation and distance to the test mean.

  2. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    We reused its GPL extraction recipe, chronological first-five and final-five pulse rule, spatial pair definitions, and pinned source provenance. We freshly rebuilt all eight source CRP files and checked every compact array and table.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis used processed SEEG source files from OpenNeuro ds004696 snapshot 1.0.1.