sciscape Publications
← All publications

Two components from five early pulses captured 29.8 percent of later SEEG variation at 20 to 500 ms after removal of the early mean direction in eight patients

This study tested a small response space for brain-computer interfaces that record after stimulation. The public SEEG data came from OpenNeuro ds004696 version 1.0.1. The test used 886 eligible bipolar readouts at 86 sites in eight patients with epilepsy. At each readout, the first five good pulses defined a mean waveform direction. After removal of that direction, two early principal components captured 29.8 percent of centered residual variation in the final five pulses at 20 to 500 ms. A separate fit before each pulse captured 27.5 percent. The equal-patient paired difference was 2.35 percentage points. The descriptive 95 percent patient bootstrap interval was 0.69 to 4.31 points. The training fraction was 80.8 percent. The small control difference limits a neural interpretation. The package preserves the Gram score, its proof, pulse products, source hashes, tables, figures, an eight-file source audit, and retrieval code. The score uses observed later voltage and the later group mean. It does not forecast an unseen response or measure a lasting mean shift.

stereoelectroencephalography · electrical stimulation · evoked potentials · brain-computer interface · principal components · waveform variability · limbic system · OpenNeuro

Admitted 3 citing publications

References

7
  1. usesLater pulse variation accounted for 72.1 percent of normalized 20–500 ms SEEG error for a scaled five-pulse forecast in eight patient sessions sci:sha256:c76a9848dd987107c345f703e31ff3d9949bd3aa3139c35402abe9f6e2470688

    Uses its credited inherited extraction code for contact parsing, region definitions, and analysis windows. The code and source lineage were preserved through the all-pulse parent publication.

  2. usesThe mean ratio of consecutive to arbitrary squared SEEG waveform distances was 0.992 at 20–500 ms in eight patients sci:sha256:7772d57bfdee850ed680e7353c67d8ecc95969cd51d402613157a1df8cf0e9fb

    Uses its exact all-pulse Gram matrices, selection tables, source metadata, pinned source receipts, extraction recipe, and known duplicate-record provenance. The new analysis tests transfer of residual waveform components from the first five pulses to later pulses. This is the same cohort, not an independent replication.

  3. usesIdeal signed scale changes left 84.5 percent of 20–500 ms SEEG error for a fixed five-pulse waveform in eight patient sessions sci:sha256:c1013f1f75ee1d942a3ee7287ce6ea0c2a5f9632b77790eb3acd7cd28e98b3b6

    Its ideal scale-adjustment result motivated a test of stable waveform directions beyond the early mean direction. The present endpoint is centered later residual variation, so its denominator differs from the prior forecast-error endpoint.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The study analyzes the processed SEEG derivatives from OpenNeuro ds004696 version 1.0.1.

  5. doi:10.1523/JNEUROSCI.2201-22.2023
  6. supportsdoi:10.1111/epi.17528

    This paper reports prior trial-by-trial response amplitude variability during SEEG mapping, as cited for background.

  7. usesdoi:10.1371/journal.pcbi.1011105

    The archived source derivatives use Canonical Response Parameterization; this is the cited method paper.

Cited by

3 publications

Public catalog entries on Sciscape.