sciscape Publications
← All publications

F limits covered 89.8 percent of later three-coefficient SEEG responses after five fit pulses at 86 selected sites in eight patients

We tested joint limits for recorded brain stimulation responses using public SEEG data from OpenNeuro ds004696, version 1.0.1. Five pulses fitted each site model; 612 later pulses at 86 selected sites in eight patients were tested. Three fixed cosine coefficients formed each response vector, and patients had equal weight after averaging sites. Gaussian limits covered 52.5% of later vectors. Finite-sample F limits covered 89.8% (descriptive 95% interval 85.1–94.1%), with 26.08 times the Gaussian volume. A Student t box covered 90.5% at 40.2% of the F volume. With four coefficients, the F volume ratio rose to 13,186.35. The benchmark shows the cost of covariance uncertainty with few fit pulses. Readout selection, patient differences, and incomplete waveform coverage limit transfer. The exact F law requires independent normal vectors and a fixed readout; these conditions were not established in this cohort. The evidence supports further tests of response limits for brain-computer interfaces, but does not establish a clinical alarm. The SCI package preserves inputs, results, figures, source records, and the full scientific text; GPL analysis and retrieval scripts are omitted, so the published payload cannot run the original replay.

stereoelectroencephalography · brain-computer interface · prediction limits · finite-sample F distribution · covariance uncertainty · electrical brain stimulation · OpenNeuro ds004696

Admitted 1 citing publication

References

5
  1. usesPast pulse updates reduced normalized 20–500 ms SEEG forecast error versus fixed five-pulse templates at 86 selected sites in eight epilepsy sessions sci:sha256:fd07147e53abc31f50ad87cee1d777a9d91b45b3d2a172703485899005f00530

    Its inherited range downloader checks pinned source sizes and hashes. The recipe holds one derivative file at a time.

  2. usesResponse correlations gave no clear loss reduction with five fit pulses and 50% shrink at 83 SEEG sites in eight sessions sci:sha256:0bef106b1ca9c41fac09e6a5802d56ecb71132bf5c518aba74fbeecbb337ddd0

    Its low joint Gaussian coverage motivated the test of uncertainty from five fit pulses. This study uses fixed temporal coefficients. It does not reuse that study's spatial features or fitted models.

  3. usesA 41-sample variance mean reduced later normal SEEG voltage log loss with five fit pulses at 86 selected sites in eight patients sci:sha256:d47d65dff1fff45ad55676c3ea2d2a6e04054077335ddce8e6c77b8bee292724

    Its exact voltage windows, fixed readout choices, pulse maps, source metadata, and retrieval code supplied this benchmark.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analyzed SEEG windows and pulse tables derive from OpenNeuro ds004696, version 1.0.1.

  5. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.