Mean ranks gave 25.2% patient mean onset label recall with 10% contact budgets in 36 patients with two SEEG records
We tested contact selection in 36 patients from public OpenNeuro ds004100, version 1.1.3. Each patient had two 120 second SEEG records. All rules had the same 10 percent contact quota, with integer rounding. Patient mean onset label recall was 20.5 percent for one record. It was 25.2 percent for mean ranks and 22.6 percent for minimum ranks. The mean rank gain was 4.68 percentage points. Its unadjusted 95 percent bootstrap interval was 0.35 to 9.35 points. Neither planned comparison passed Holm correction. The corrected p values were 0.100 and 0.194. This does not prove a zero effect. An exploratory equal time check used 112 seconds per list. Across record mean ranks gained 2.35 points over within record pairs. The interval was -0.22 to 5.31 points. The package supplies a fixed budget benchmark, code, contact data, every list, figures, random draws, and pinned source instructions. All 72 source prefixes and band powers passed checks. A second run reproduced all 22 numerical files byte for byte. The study tests source clinical labels. It does not test treatment outcomes or external prediction.
stereoelectroencephalography · epilepsy · seizure onset zone · contact selection · rank aggregation · fixed contact budget · patient mean recall · low frequency power
References
5- usesSmaller scaled contact numbers ranked seizure onset labels with mean AUC 0.676 in two short SEEG records for each of 36 patients sci:sha256:9f7fc3dd7992b9fb698f1a4fbde362238501922fcf4ecace3730b64919403c1e
This study supplied the scaled contact number comparison method. We applied that method to the same contact quota as the signal rank rules.
- usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33
This source supplied all 72 window power files, labels, extraction code, metadata, and pinned source versions. These inputs enabled the fixed contact budget study.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analysis used the HUP iEEG Epilepsy Dataset, ds004100 snapshot 1.1.3, with source metadata pinned to commit da07f99bcd7a801f86191eceb2d35b0520c55d1a.
- supportsdoi:10.1038/s41598-019-42347-y
This paper supplied the expected direction of the low frequency score used in this transfer test.
- doi:10.1093/braincomms%2Ffcab231
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.