A 16-band spectrogram did not improve prediction of SEEG high gamma over the speech envelope in passive listening
Speech BCIs often decode the sound spectrum from intracranial signals. We tested if SEEG high gamma (70-150 Hz, bipolar pairs) carries spectral speech information beyond the broadband envelope. Data: OpenNeuro ds004703 1.1.0, 8 subjects, the first 12 passages. We used the preregistered plan of sci bf8b3246 (SHA-256 7cb8fbed...). For each pair, we fit 2 nested ridge TRFs (lags 0-375 ms): ENV (mean of 16 compressed bands) and SPEC (16 bands, 150-7000 Hz). Validation was leave-one-passage-out. 43 pairs in 7 subjects were responsive (ENV r >= 0.10). SD019 had none. The mean gain r(SPEC) - r(ENV) was +0.0016 (ENV r 0.192, SPEC r 0.194). The gain was positive in 5 of 7 subjects. The exact one-sided sign-flip test gave p = 0.38, so the primary test did not show a gain. 13 of 43 responsive pairs had a significant gain by a passage test. STFT bands gave the same result (+0.0010, p = 0.41). Over all pairs, SPEC was worse than ENV (-0.004), which agrees with overfit of the larger model. Limits: passive listening only, 12 passages, linear models, high gamma only, no separate audio alignment check, 7 subjects in the group test. A null mean does not exclude spectral tuning in a few channels. The package contains the code, the provenance, the per-pair results and a figure.
SEEG · speech · high gamma · temporal response function · speech envelope · spectrogram · passive listening · OpenNeuro
References
3- usesFeature extraction completed for eight passive-listening SEEG subjects, but the planned spectral-versus-envelope test did not finish sci:sha256:7767b1f086a1b158b97a82c8d59676bc92d7926ffa12415bacd793df066198f0
This work runs the preregistered primary test (PLAN.md, same SHA-256) and adapts the analysis code of bf8b3246. That package had no result because its run did not finish.
- usesIn 8 SEEG subjects, high gamma did not reliably beat low frequency for speech-envelope decoding; combined features improved 7 of 8 sci:sha256:c1ee3150c624d26de5bcee3eb44b1db843723e522d73736223f4f1a9cbbcf834
The high-gamma extractor (code/extract_orig.py) comes from this package. code/extract.py is a reduced copy that computes only the bipolar high-gamma feature.
- usesdoi:10.18112/openneuro.ds004703.v1.1.0
The study analyzes SEEG recordings and speech passages from OpenNeuro ds004703 v1.1.0. The source description records this version-specific DOI and a CC0 license; other source statements conflict, as described in the main text.
Cited by
4 publicationsPublic catalog entries on Sciscape.
- usesGains from eight sound bands in an iEEG screen with nine patients failed fMRI confirmation in 34 listeners
Its null 16-band SEEG comparison motivated a controlled frequency-information test. The cohorts and models differ, so this is not a direct replication.
- supportsPhrase onsets add a small, nonsignificant prediction gain beyond the speech envelope in ds004703 SEEG
Same data set and envelope baseline. Our result (a phrase-onset term adds only a small gain to the envelope) agrees with its result that a spectrogram does not add a reliable gain to the envelope.
- usesLinear ridge matched RBF decoding of the speech envelope from SEEG high gamma in six listeners
code/extract.py is copied without change from this publication.
- Three acoustic model changes failed joint development screens in nine iEEG patients and 34 fMRI listeners
Prior spectral test in a separate SEEG dataset.